journal article·2026-03

Highly Selective and Flexible HCl Sensor Enabled by Ag 2 O‐Functionalized Graphene Micropatterns

Seungsoo Kim, Jaehyun Kim, Taehoon Kim, Yeonhoo Kim, Jaegun Sim, Ji heon Lim, Woo seok Cheon, Sung Jin Seo, Seon Yong Lee, Hyeong Seok Lee, Gwan‐Hyoung Lee, Zhigang Zhu, Soong Ju Oh, Byung Hee Hong, Ho Won Jang

Small· Volume 22· Issue 15
Publisher page

Abstract

ABSTRACT Graphene is considered one of the most attractive materials for next‐generation gas sensor platforms owing to its high performance at room temperature, transparency, and flexibility. However, graphene exhibits inherent low selectivity and irreversible behavior in gas sensing. While various methods such as doping, grain control and metal decoration have been extensively employed to functionalize graphene, graphene sensors for strong acids have remained underexplored. Here, we present unprecedented room‐temperature hydrogen chloride (HCl) detection of self‐activated graphene functionalized by silver oxide (Ag 2 O) nanoparticles. Ag 2 O‐functionalized graphene micropatterns show ultra‐high selectivity to HCl with an extremely low detection limit of 5.617 parts per trillion (ppt). Density functional theory (DFT) calculations demonstrate that the strong interaction between Ag 2 O and HCl, induced by charge depletion in the center parts of Ag 2 O, promotes the attraction of HCl molecules. Furthermore, the unique properties of graphene, such as Joule heating and corrosion resistance to strong acids, significantly reduce power consumption, improve humidity stability, and ensure long‐term stability, which have been major limitations of conventional acid sensors. This work proposes the functionalization of graphene by metal nanoparticles, extending beyond the limitations of conventional sensors, and demonstrates the potential of graphene as a next‐generation sensor platform for flexible electronics.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Gas Sensing Nanomaterials and Sensors · Graphene research and applications · 2D Materials and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Science and Engineering Research Institute of Advanced Materials Seoul National University Seoul Republic of Korea

Strategic Technology Research Institute Korea Research Institute of Standards and Science Daejeon Republic of Korea

School of Electrical and Electronics Engineering Chung‐Ang University Seoul Republic of Korea

Graphene Research Center Advanced Institute of Convergence Technology Suwon Republic of Korea

School of Health Science and Engineering University of Shanghai for Science and Technology Shanghai China

Department of Materials Science and Engineering Korea University Seoul Republic of Korea

Department of Chemistry Seoul National University Seoul Republic of Korea

Advanced Institute of Convergence Technology Seoul National University Suwon Republic of Korea

Funding

Ministry of Science and ICT, South Korea

References (54)

Show source-provided references
1. 10.1038/s41467‐018‐03938‐x10.1038/s41467‐018‐03938‐x ↗
2. 10.1038/nchem.36010.1038/nchem.360 ↗
3. 10.1016/j.snb.2024.13545510.1016/j.snb.2024.135455 ↗
4. 10.1021/acssensors.6b0003110.1021/acssensors.6b00031 ↗
5. 10.46670/JSST.2024.33.5.26510.46670/JSST.2024.33.5.265 ↗
6. 10.1038/s41928‐018‐0162‐510.1038/s41928‐018‐0162‐5 ↗
7. 10.1007/s13391‐019‐00175‐210.1007/s13391‐019‐00175‐2 ↗
8. 10.1021/acs.inorgchem.2c0274210.1021/acs.inorgchem.2c02742 ↗
9. 10.1007/s42341-023-00490-410.1007/s42341-023-00490-4 ↗
10. 10.1039/C6TA05943K10.1039/C6TA05943K ↗
11. 10.1002/adfm.20210070910.1002/adfm.202100709 ↗
12. 10.1016/j.jscs.2020.02.00110.1016/j.jscs.2020.02.001 ↗
13. 10.1016/j.synthmet.2010.09.02610.1016/j.synthmet.2010.09.026 ↗
14. 10.1021/acsomega.8b0005410.1021/acsomega.8b00054 ↗
15. 10.3390/polym1207159110.3390/polym12071591 ↗
16. 10.1007/s42823‐021‐00276‐910.1007/s42823‐021‐00276‐9 ↗
17. 10.46670/JSST.2024.33.6.43910.46670/JSST.2024.33.6.439 ↗
18. 10.1002/inf2.1242710.1002/inf2.12427 ↗
19. 10.1038/s41378‐024‐00697‐210.1038/s41378‐024‐00697‐2 ↗
20. 10.1021/acs.analchem.8b0555410.1021/acs.analchem.8b05554 ↗
21. 10.1007/s42341‐024‐00544‐110.1007/s42341‐024‐00544‐1 ↗
22. 10.1002/admi.20190132910.1002/admi.201901329 ↗
23. 10.1038/s41598‐024‐54110‐z10.1038/s41598‐024‐54110‐z ↗
24. 10.1038/s41699‐024‐00452‐110.1038/s41699‐024‐00452‐1 ↗
25. 10.1002/adfm.20220766910.1002/adfm.202207669 ↗
26. 10.1007/s40820‐020‐00503‐410.1007/s40820‐020‐00503‐4 ↗
27. 10.1038/s41467‐024‐50443‐510.1038/s41467‐024‐50443‐5 ↗
28. 10.1038/s41524‐024‐01329‐z10.1038/s41524‐024‐01329‐z ↗
29. 10.1002/adfm.20242401810.1002/adfm.202424018 ↗
30. 10.1002/adfm.20210733010.1002/adfm.202107330 ↗
31. 10.1002/adfm.20200766110.1002/adfm.202007661 ↗
32. 10.55713/jmmm.v34i3.203810.55713/jmmm.v34i3.2038 ↗
33. 10.1002/adfm.20190975610.1002/adfm.201909756 ↗
34. 10.1002/adfm.20210692510.1002/adfm.202106925 ↗
35. 10.1002/adfm.20240163110.1002/adfm.202401631 ↗
36. Clomipramine Determination by Potentiometric PVC Membrane and Carbon Paste Sensors
37. 10.1186/s13065-023-00938-x10.1186/s13065-023-00938-x ↗
38. 10.2174/156802662366623021011574010.2174/1568026623666230210115740 ↗
39. 10.1007/s11664‐021‐09082‐510.1007/s11664‐021‐09082‐5 ↗
40. 10.1002/elan.20210016510.1002/elan.202100165 ↗
41. 10.1002/adfm.20240788510.1002/adfm.202407885 ↗
42. 10.1002/adfm.20211334810.1002/adfm.202113348 ↗
43. 10.1002/adfm.20120019110.1002/adfm.201200191 ↗
44. 10.1002/adma.20200482710.1002/adma.202004827 ↗
45. 10.1021/acsnano.5b0468010.1021/acsnano.5b04680 ↗
46. 10.1038/s41928‐020‐0402‐310.1038/s41928‐020‐0402‐3 ↗
47. 10.1007/s13391‐022‐00400‐510.1007/s13391‐022‐00400‐5 ↗
48. 10.1016/j.snb.2021.13069610.1016/j.snb.2021.130696 ↗
49. 10.1038/nnano.2013.4610.1038/nnano.2013.46 ↗
50. 10.1039/C7NR01120B10.1039/C7NR01120B ↗
51. 10.1038/s41467‐019‐09565‐410.1038/s41467‐019‐09565‐4 ↗
52. 10.3762/bjnano.9.26410.3762/bjnano.9.264 ↗
53. 10.1002/advs.20160031910.1002/advs.201600319 ↗
54. 10.1007/s13391‐024‐00534‐810.1007/s13391‐024‐00534‐8 ↗