Source abstract
Abstract
Abstract Urolithiasis stands as a prevalent ailment within the urinary system, with hyperoxaluria and hypocitraturia being the most frequent manifestations characterized by excessive oxalic acid (OA) and deficient citric acid (CA) levels in urine. Detecting these compounds in urine quantitatively holds paramount importance for early urolithiasis screening. Existing methodologies fall short in achieving simultaneous and on‐site identification of OA and CA, posing challenges for accurate urolithiasis screening. Addressing this concern, the study successfully accomplishes the concurrent identification of OA and CA in urine through a combination of dual‐spectral analysis and biomimetic peroxidase utilization. Bovine serum albumin and dithiothreitol‐modified copper nanoclusters (BSA‐DTT‐CuNCs) are employed as biomimetic peroxidases, effectively mitigating interference and enabling the simultaneous determination of OA and CA. The quantification range spans from 0 to 12 mm for OA and 0.5 to 2.5 mm for CA, with detection limits of 0.18 and 0.11 mm, respectively. To facilitate swift and on‐location urine analysis, a fully automated urine analyzer (FAUA) is introduced that streamlines the process of biomarker pretreatment and identification within urine samples. Validation with real urine samples from urolithiasis patients demonstrates the method's diagnostic precision, highlighting the dual‐spectral technique and analyzer's promising role in urolithiasis screening.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Selenium in Biological Systems · Kidney Stones and Urolithiasis Treatments · Mercury impact and mitigation studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Biosensor National Special Laboratory Key Laboratory of Biomedical Engineering of Ministry of Education Department of Biomedical Engineering Zhejiang University Hangzhou 310027 China
Department of Respiratory Medicine Sir Run Run Shaw Hospital Medical School of Zhejiang University Hangzhou China
Research Center for Quantum Sensing Zhejiang Lab Hangzhou 310000 China
State Key Laboratory of Transducer Technology Chinese Academy of Sciences Shanghai 200050 China
Binjiang Institute of Zhejiang University Hangzhou 310053 China
Funding
National Key Research and Development Program of China · National Natural Science Foundation of China
References (37)
Show source-provided references
3. Romero V. · Rev Urol · 2010 · 12
10. Zuckerman J. M. · Rev Urol · 2009 · 11 · 134