Method to determine electrochemical potential gradients without reinforcement connection in concrete structures
Source abstract
Abstract
Abstract A suitable condition assessment of a structure is usually based on comprehensive non-destructive measurements to locate the relevant critical areas. Electrochemical potential mapping is an approved method to detect areas with a high risk of chloride induced corrosion in concrete structures. A novel approach has been developed to locate critical areas without a reinforcement connection by using three external electrodes. As result a vector is calculated which points directly to the critical area near the sensor position, comparable with a compass. This method allows an immediate identification of critical areas on site. In this paper the methodology is explained and measuring results are compared to the conventional method.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Smart Materials for Construction · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (4)
Show source-provided references
1. Half-cell potentials and the corrosion of steel in concrete
2. RILEM TC 154-EMC, Elsener B, Andrade C, Gulikers J, Raupach M. Half-cell potential measurements – potential mapping on reinforced concrete structures. In: Materials and structures (RILEM) 36, vol. 261. 2003. p. S.461–71.10.1617/13718 ↗
3. American Society of Testing and Materials. Standard test method for determining effects of chemical admixtures on corrosion of embedded steel reinforcement in concrete exposed to chloride environments. ASTM C876-09.
4. The use of potential wheel to survey reinforced concrete structures