journal article·2011-02-22

Highly Sensitive Biosensing Using Arrays of Plasmonic Au Nanodisks Realized by Nanoimprint Lithography

Seung-Woo Lee, Kyeong-Seok Lee, Junhyoung Ahn, Jae-Jong Lee, Min-Gon Kim, Yong-Beom Shin

ACS Nano· Volume 5· Issue 2
Publisher page

Abstract

We describe the fabrication of elliptical Au nanodisk arrays as a localized surface plasmon resonance (LSPR) sensing substrate for clinical immunoassay via thermal nanoimprint lithography (NIL) and enhancement in the sensitivity of the detection of the prostate-specific antigen (PSA) using the precipitation of 5-bromo-4-chloro-3-indolyl phosphate p-toluidine/nitro blue tetrazolium (BCIP/NBT), catalyzed by alkaline phosphatase. Au nanodisks were fabricated on glass through an unconventional tilted evaporation, which could preserve the thickness of imprinted resists and create an undercut beneficial to the subsequent lift-off process without any damage to pattern dimension and the glass while removing the residual polymers. To investigate the optically anisotropic property of the LSPR sensors, a probe light with linear polarization parallel to and perpendicular to the long axis of the elliptical nanodisk array was utilized, and their sensitivity to the bulk refractive index (RI) was measured as 327 and 167 nm/RIU, respectively. To our knowledge, this is the first application of enzyme-substrate reaction to sandwich immunoassay-based LSPR biosensors that previously suffered from a low sensitivity due to the short penetration depth of the plasmon field, especially when large-sized antibodies were used as bioreceptors. As a result, a large change in local refractive index because of the precipitation on the Au nanodisks amplified the wavelength shift of the LSPR peak in the vis-NIR spectrum, resulting in femtomolar detection limits, which was ∼10(5)-fold lower than the label-free detection without the enzyme precipitation. This method can be extended easily to the other clinical diagnostics with a high sensitivity.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Nanofabrication and Lithography Techniques · Plasmonic and Surface Plasmon Research · Monoclonal and Polyclonal Antibodies Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Korea Research Institute of Bioscience and Biotechnology (KRIBB), 111 Gwahangno, Yuseong-gu, Daejeon 305-806, South Korea

Korea Institute of Science and Technology (KIST), 39-1 Hawolgok-dongWolsong-gil, 5, Seong-buk-gu, Seoul 136-791, South Korea

University of Science & Technology (UST), 176 Gajung-dong, Yuseong-gu, Daejeon 305-350, South Korea

Korea Institute of Machinery and Materials (KIMM), 104 Sinseongno, Yuseong-gu, Daejeon 305-343, South Korea

References (30)

Show source-provided references
1. Stewart M. · Chem. Rev. · 2008 · 108 · 49410.1021/cr068126n ↗
2. Haes A. · Expert Rev. Mol. Diagn. · 2004 · 4 · 52710.1586/14737159.4.4.527 ↗
3. Gomez-Hens A. · Trends Anal. Chem. · 2008 · 27 · 39410.1016/j.trac.2008.03.006 ↗
4. Haynes C. · J. Phys. Chem. B · 2001 · 105 · 559910.1021/jp010657m ↗
5. Kelly K. · J. Phys. Chem. B · 2003 · 107 · 66810.1021/jp026731y ↗
6. Chan G. H. · J. Phys. Chem. C · 2008 · 112 · 1395810.1021/jp804088z ↗
7. Anker J. · Nat. Mater. · 2008 · 7 · 44210.1038/nmat2162 ↗
8. Stewart M. E. · Proc. Natl. Acad. Sci. U.S.A. · 2006 · 103 · 1714310.1073/pnas.0606216103 ↗
9. Stewart M. E. · Anal. Chem. · 2009 · 81 · 598010.1021/ac900819j ↗
10. Haes A. J. · J. Am. Chem. Soc. · 2002 · 124 · 1059610.1021/ja020393x ↗
11. Haes A. · J. Am. Chem. Soc. · 2005 · 127 · 226410.1021/ja044087q ↗
12. Zheng Y. · J. Appl. Phys. · 2008 · 103 · 01430810.1063/1.2828146 ↗
13. Lucas B. · Adv. Mater. · 2008 · 20 · 112910.1002/adma.200700225 ↗
14. Marinakos S. · Anal. Chem. · 2007 · 79 · 527810.1021/ac0706527 ↗
15. Lee S. · Anal. Chem. · 2009 · 81 · 445010.1021/ac900276n ↗
16. Chou S. · J. Vac. Sci. Technol., B · 1996 · 14 · 412910.1116/1.588605 ↗
17. Zankovych S. · Nanotechnology · 2001 · 12 · 9110.1088/0957-4484/12/2/303 ↗
18. Hu W. · J. Vac. Sci. Technol., A · 2007 · 25 · 129410.1116/1.2484497 ↗
19. Haes A. · Anal. Bioanal. Chem. · 2004 · 379 · 92010.1007/s00216-004-2708-9 ↗
20. Shin Y.-B. · Biosens. Bioelectron. · 2007 · 22 · 230110.1016/j.bios.2006.12.028 ↗
21. Kim H. · Sensors · 2009 · 9 · 233410.3390/s90402334 ↗
22. Frederix F. · Anal. Chem. · 2003 · 75 · 689410.1021/ac0346609 ↗
23. Kim M. · J. Immunol. Methods · 2005 · 297 · 12510.1016/j.jim.2004.12.007 ↗
24. Li Y. · Anal. Chem. · 2007 · 79 · 108210.1021/ac061849m ↗
25. Faircloth B. · J. Vac. Sci. Technol., B · 2000 · 18 · 186610.1116/1.1305272 ↗
26. Draine B. T. · J. Opt. Soc. Am. A · 1994 · 11 · 149110.1364/JOSAA.11.001491 ↗
27. Healy D. · Trends Biotechnol. · 2007 · 25 · 12510.1016/j.tibtech.2007.01.004 ↗
28. Yonzon C. · Talanta · 2005 · 67 · 43810.1016/j.talanta.2005.06.039 ↗
29. Huang L. · Biosens. Bioelectron. · 2005 · 21 · 48310.1016/j.bios.2004.11.016 ↗
30. Besselink G. · Anal. Biochem. · 2004 · 333 · 16510.1016/j.ab.2004.05.009 ↗