Distance-Based Visual miRNA Biosensor with Strand Displacement Amplification-Mediated DNA Hydrogel Assembly
Source abstract
Abstract
We have developed a novel paper biosensor for miRNA assays by monitoring the seepage flow distance along the strip. Target miRNA-initiated strand displacement polymerization produces abundant DNA strands, which assist the assembly of the DNA hydrogel. The phase transition is successfully demonstrated by elastography and electrochemical techniques. The variation of flow distance is highly related to the viscosity of the DNA hydrogel. By visual observation of the distance, highly sensitive quantification of miRNA can be achieved. The limit of detection is estimated to be 1 fM, which is quite low. The utility in clinical samples is also verified by consistent results of the standard quantitative reverse transcription PCR (qRT-PCR) technique. This approach is not only highly sensitive but also exhibits the merits of convenient operation and low cost, meeting the requirements of point-of-care testing. It shows significant potential for the applications of biological studies and clinical disease diagnosis.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced biosensing and bioanalysis techniques · Biosensors and Analytical Detection · RNA Interference and Gene Delivery
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
Shandong Laboratory of Advanced Biomaterials and Medical Devices in Weihai, Weihai 264200, China
Funding
Science Fund for Distinguished Young Scholars of Jiangsu Province · National Natural Science Foundation of China · Project of Shandong Provincial Laboratory
References (33)
Show source-provided references
1. 10.1038/s41467-023-43293-010.1038/s41467-023-43293-0 ↗
2. 10.1038/nature2403410.1038/nature24034 ↗
3. 10.1038/ni.275810.1038/ni.2758 ↗
4. 10.1038/s41556-023-01179-910.1038/s41556-023-01179-9 ↗
5. 10.1038/nature1011210.1038/nature10112 ↗
6. 10.1021/acs.analchem.1c0440110.1021/acs.analchem.1c04401 ↗
7. 10.1038/s41467-019-11826-110.1038/s41467-019-11826-1 ↗
8. 10.1021/acs.analchem.3c0492010.1021/acs.analchem.3c04920 ↗
9. 10.1016/j.cej.2023.14323010.1016/j.cej.2023.143230 ↗
10. 10.1016/j.cej.2024.15015110.1016/j.cej.2024.150151 ↗
11. 10.1039/D0CC01530J10.1039/D0CC01530J ↗
12. 10.1039/C9SC02281C10.1039/C9SC02281C ↗
13. 10.1039/D2CC02821B10.1039/D2CC02821B ↗
14. 10.1016/j.snb.2022.13230710.1016/j.snb.2022.132307 ↗
15. 10.1021/accountsmr.3c0015110.1021/accountsmr.3c00151 ↗
16. 10.1021/acs.analchem.2c0561710.1021/acs.analchem.2c05617 ↗
17. 10.1021/acs.analchem.2c0360610.1021/acs.analchem.2c03606 ↗
18. 10.1021/acssensors.0c0005010.1021/acssensors.0c00050 ↗
19. 10.1021/acs.analchem.8b0055910.1021/acs.analchem.8b00559 ↗
20. 10.1021/acssensors.1c0062410.1021/acssensors.1c00624 ↗
21. 10.1016/j.cclet.2023.10846210.1016/j.cclet.2023.108462 ↗
22. 10.1021/acs.analchem.2c0295710.1021/acs.analchem.2c02957 ↗
23. 10.1021/acsnano.0c0639210.1021/acsnano.0c06392 ↗
24. 10.1021/acs.analchem.1c0464910.1021/acs.analchem.1c04649 ↗
25. 10.1039/C9TB02584G10.1039/C9TB02584G ↗
26. 10.1021/acs.analchem.8b0498110.1021/acs.analchem.8b04981 ↗
27. 10.1002/anie.20141150810.1002/anie.201411508 ↗
28. 10.1016/j.trac.2024.11762810.1016/j.trac.2024.117628 ↗
29. 10.1038/nnano.2012.21110.1038/nnano.2012.211 ↗
30. 10.1021/acs.nanolett.3c0344810.1021/acs.nanolett.3c03448 ↗
31. 10.1002/adma.20100334310.1002/adma.201003343 ↗
32. 10.1016/0021-9797(81)90031-X10.1016/0021-9797(81)90031-X ↗
33. 10.1016/0032-3861(87)90289-810.1016/0032-3861(87)90289-8 ↗