journal article·2020-01-31Open access

Biocompatible and flexible paper-based metal electrode for potentiometric wearable wireless biosensing

Toshiya Sakata, Masami Hagio, Akiko Saito, Yuto Mori, Masayuki Nakao, Kazuhiko Nishi

Abstract

A paper-based electrode is a very attractive component for a disposable, nontoxic, and flexible biosensor. In particular, wearable biosensors, which have recently been attracting interest, not only require these characteristics of paper-based electrodes but must also be able to detect various ions and biomolecules in biological fluids. In this paper, we demonstrate the detection ability of paper-based metal electrodes for wearable biosensors as part of a wireless potentiometric measurement system, focusing on the detection of pH and sodium ions. The paper-based metal electrodes were obtained by simply coating a silicone-rubber-coated paper sheet with a Au (/Cr) thin film by sputtering then modifying it with different functional membranes such as an oxide membrane (Ta2O5) and a fluoropolysilicone (FPS)-based Na+-sensitive membrane, corresponding to the targeted ions. Satisfactory and stable detection sensitivities of the modified paper-based Au electrodes were obtained over several weeks even when they were bent to a radius of curvature in the range of 6.5 to 25 mm, assuming use in a flexible body patch biosensor. Moreover, the Na+ concentration in a sweat sample was evaluated using the paper-based Au electrode with the FPS-based Na+-sensitive membrane in a wireless and real-time manner while the electrode was bent. Thus, owing to their complex mesh structure, flexible paper sheets should be suitable for use as potentiometric electrodes for wearable wireless biosensors.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Conducting polymers and applications · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Engineering, School of Engineering, the University of Tokyo, Tokyo, Japan

Department of Mechanical Engineering, School of Engineering, the University of Tokyo, Tokyo, Japan

References (40)

Show source-provided references
1. 10.1038/nature1652110.1038/nature16521 ↗
2. 10.1038/s41586-018-0536-x10.1038/s41586-018-0536-x ↗
3. 10.1038/d41586-019-02143-010.1038/d41586-019-02143-0 ↗
4. 10.1093/clinchem/3.3.16310.1093/clinchem/3.3.163 ↗
5. Charlton DE Test device and method for colored particle immunoassay. U. S. Patent 2002, US6485982B1.
6. 10.1002/elan.20140003610.1002/elan.201400036 ↗
7. 10.1021/acs.analchem.6b0476910.1021/acs.analchem.6b04769 ↗
8. 10.1021/acs.chemrev.7b0002410.1021/acs.chemrev.7b00024 ↗
9. 10.1149/2.0791706jes10.1149/2.0791706jes ↗
10. 10.1002/pssa.20170046810.1002/pssa.201700468 ↗
11. 10.2116/analsci.34.710.2116/analsci.34.7 ↗
12. 10.1016/j.snb.2018.03.02010.1016/j.snb.2018.03.020 ↗
13. 10.1021/j100871a02310.1021/j100871a023 ↗
14. 10.1109/TBME.1970.450268810.1109/TBME.1970.4502688 ↗
15. 10.1109/TBME.1974.32433810.1109/TBME.1974.324338 ↗
16. 10.1021/ac60363a00510.1021/ac60363a005 ↗
17. 10.1109/TBME.1978.32624510.1109/TBME.1978.326245 ↗
18. McBride PT · Anal Chim Acta · 1979 · 108 · 239
19. 10.1021/acs.analchem.8b0468110.1021/acs.analchem.8b04681 ↗
20. 10.1021/acsomega.9b0162910.1021/acsomega.9b01629 ↗
21. 10.1039/B204444G10.1039/B204444G ↗
22. 10.1021/ac400101810.1021/ac4001018 ↗
23. 10.1021/acs.analchem.7b0368810.1021/acs.analchem.7b03688 ↗
24. 10.1039/C8NR02950D10.1039/C8NR02950D ↗
25. 10.1038/s41598-018-26719-410.1038/s41598-018-26719-4 ↗
26. 10.1021/acs.analchem.8b0307010.1021/acs.analchem.8b03070 ↗
27. 10.3390/s1908178410.3390/s19081784 ↗
28. 10.1080/14686996.2019.165651610.1080/14686996.2019.1656516 ↗
29. 10.1002/celc.20170041910.1002/celc.201700419 ↗
30. 10.1021/acs.analchem.6b0224610.1021/acs.analchem.6b02246 ↗
31. 10.1016/S0003-2670(00)80978-210.1016/S0003-2670(00)80978-2 ↗
32. 10.1177/00045632940310010310.1177/000456329403100103 ↗
33. 10.1016/0021-9673(95)00132-710.1016/0021-9673(95)00132-7 ↗
34. 10.1021/acssensors.9b0059710.1021/acssensors.9b00597 ↗
35. 10.1111/j.1365-201X.2004.01305.x10.1111/j.1365-201X.2004.01305.x ↗
36. 10.1038/s41598-018-20978-x10.1038/s41598-018-20978-x ↗
37. 10.1021/ac50006a00810.1021/ac50006a008 ↗
38. 10.1016/S0003-2670(96)00284-X10.1016/S0003-2670(96)00284-X ↗
39. 10.1016/j.snb.2012.11.05410.1016/j.snb.2012.11.054 ↗
40. 10.1146/annurev-anchem-061318-11491010.1146/annurev-anchem-061318-114910 ↗