Abstract The main elements of a developed portable radiometric system (PRS) and options for its application are discussed. When developing the PRS detector modules, silicon photomultipliers were used that made it possible to considerably reduce the size of these modules. Devices and systems of this kind find application in solving various problems of medical radionuclide diagnostics that require an increased field of view, an extended research time range, and mobility. The main goal of this work was to find the optimal configuration of PRS elements to ensure its minimum size and, at the same time, the maximum radiation detection efficiency, taking into account the features of the objects under study and the kinetics of the processes occurring in them. An algorithm for selecting the minimum amount of activity of a radioactive preparation required for each study is additionally considered.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Medical Imaging Techniques and Applications · Radioactive Decay and Measurement Techniques · Chemical Reactions and Isotopes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. Tsui, B.M., Quantitative single-photon emission computed tomography: Basics and clinical considerations, Semin. Nucl. Med., 1994, no. 24, pp. 38–65.10.1016/S0001-2998(05)80248-X ↗
2. Bailey, D.L., Nuclear Medicine Physics. A Handbook for Teachers and Students, Bailey, D.L., Humm, J.L., Todd-Pokropek, A., Aswegen, A., Eds., Vienna: Int. At. Energy Agency, 2014.
3. Mahadev, V., Measurement of effective renal plasma flow: Evaluation of clinical uses in combination with renography, Dynamic Studies with Radioisotopes in Medicine. Proc. Symp. Dyn. Studies Radioisot. Clin. Med. Res., Vienna: Int. At. Energy Agency, 1971, pp. 299–320.
4. Gromyko, M.V., Scintillation β-radiometer: application features and detector selection, in Fizika. Tekhnologii. Innovatsii : sb. nauchn. Tr. (Physics. Technologies. Innovation: Collect. Sci. Pap.), Yekaterinburg: Ural. Gos. Univ., 2015, pp. 47–53.
5. Prekeges, J., Nuclear Medicine Instrumentation, Washington: Jones & Bartlett, 2012.
6. Pankin, S.V., Mil’man, I.I., Sarychev, M.N., and Zelenin, A.A., Gamma radiation detection module, RF Utility Patent no. 185203 U1, applicant and patentee Stagirit Meditsinskie Innovatsii LLC, no., priority June 8, 2018, published November 26, 2018.
7. Pankin, S.V. et al., Portable radiometric system for radionuclide diagnostics, ANRI, 2018, no. 2 (93), pp. 40–47.
8. Pankin, S.V., Portable radiometric system for medical radionuclide diagnostics: Structure and main application possibilities, Biomed. Radioelektron., 2021, no. 2 (24), pp. 47–55.
9. Pankin, S.V. et al., A portable radiometric system for nuclear medicine, Rad. Meas., 2019, pp. 10-12 p.10.1016/j.radmeas.2018.12.003 ↗
10. Barna, S. et al., Clinical utility of SPECT/CT and CT-dacryocystography-enhanced dacryoscintigraphy in the imaging of lacrimal drainage system obstruction, Ann. Nucl. Med, 2019, vol. 33, no. 10, pp. 746–754.10.1007/s12149-019-01385-2 ↗
11. Chen, S. and Wang, Y., Virtual touch quantification of the salivary glands for diagnosis of primary Sjögren syndrome, J. Ultrasound Med., 2016, vol. 35, no. 12, pp. 2607–2613.10.7863/ultra.16.01085 ↗
12. Pankin, S.V. et al., A phantom model of the lacrimal and salivary glandular structures, AIP Conf. Proc., 2019, vol. 2174, p. 020152.10.1063/1.5134303 ↗
13. Kumar, Sanjay, Recent trends in industrial and other engineering applications of non destructive testing: A review, Int. J. Sci. Eng. Res., 2013, vol. 4, no. 9.
14. Baldev Raj et al., Practical Nondestructive Testing, Sawston: Woodhead, 2002.
15. Beck, R.N., Collimators for radioisotope scanning systems, in Medical Radioisotope Scanning, Vienna: Int. At. Energy Agency, 1964, pp. 211–232.
16. Resolution of the Chief State Sanitary Doctor of the Russian Federation of July 20, 2015, no. 31 on the approval of SanPin2.6.1.3288-15 Gigiyenicheskie trebovaniya po obespecheniyu radiatsionnoi bezopasnosti pri podgotovke i provedenii pozitronnoi emissionnoi tomografii (Hygienic Requirements for Ensuring Radiation Safety in the Preparation and Conduct of Positron Emission Tomography), Moscow: TSENTRMAG.
17. Lishmanov, Yu.B., Radionuklidnaya diagnostika dlya prakticheskikh vrachei (Radionuclide Diagnostics for Practitioners), Tomsk: STT, 2004.