Determining the Granularity of Radiographic Films in Accordance with ISO 11699-1
Source abstract
Abstract
Abstract— One of the important properties of industrial radiographic films that determine the clarity of the resulting image is granularity. In the technical specifications for any industrial radiographic film, the manufacturer is obliged to provide information on granularity in addition to other characteristics such as sensitivity to radiation and contrast, and the companies that attest radiographic films must evaluate it. This is required by the international standard ISO 11699-1: 2008. The granularity value (among other characteristics) determines the belonging of the radiographic film to a certain class, and, consequently, the possibility of using the film in X-ray or gamma tetsing of certain objects. To assess the granularity, specific equipment and adherence to the technology of this process, regulated by ISO 11699-1: 2008, is required. The article provides information on the assessment of granularity by means of the developed stand with dummies of the optical system and the data collection system in automatic and manual modes. The developed stand was used to assess the granularity of the D5 (Agfa) radiographic film. The obtained experimental data coincide within the permissible range with the data specified in the certificate of conformity to international standards.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Engineering Technology and Methodologies · Industrial Engineering and Technologies · Engineering and Environmental Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. Kablov, E.N., The key problem is materials, in Tendentsii i orientiry innovatsionnogo razvitiya Rossii (Trends and Guidelines for Innovative Development of Russia), Moscow: VIAM, 2015, pp. 458–464.
2. Kablov, E.N., Innovative developments at FSUE “VIAM” on the implementation of “Strategic directions for the development of materials and processing technologies for the period up to 2030,” Aviats. Mater. Tekhnol., 2015, no. 1, pp. 3–33. https://doi.org/10.18577/2071-9140-2015-0-1-3-3310.18577/2071-9140-2015-0-1-3-33 ↗
3. Kablov, E.N., New generation materials—the basis of innovation, technological leadership and national security of Russia, Intellekt. Tekhnol., 2016, vol. 2, no. 14, pp. 16–21.
4. ISO 11699-1:2008. Non-destructive testing. Industrial radiographic film. Part 1: Classification of film systems for industrial radiography, Moscow: Standartinform, 2009.
5. Kosarina, E.I., Stepanov, A.V., Demidov, A.A., and Krupnina, O.A., Sensitometer for technical radiographic films, Aviats. Mater. Tekhnol., 2016, no. 3, pp. 88–94. https://doi.org/10.18577/2071-9140-2016-0-3-88-9410.18577/2071-9140-2016-0-3-88-94 ↗
6. Hosobuchi, Y. and Ohnuma, K., Measurement of root mean square granularity of X-ray films using a commercial film scanner, Opt. Rev., 2001, vol. 8, no. 4, pp. 301–304.10.1007/s10043-001-0301-4 ↗
7. Eckel, S., Zscherpel, U., Huthwaite, P., Paul, N., and Schumm, A., Radiographic film system classification and noise characterisation by a camera-based digitisation procedure, NDT & E Int., 2020, vol. 111, article ID 102241.10.1016/j.ndteint.2020.102241 ↗
8. Kosarina, E.I., Generalov, A.S., and Demidov, A.A., Problems in the state system of standardization of the Russian Federation in the field of radiation non-destructive testing, Tr. VIAM: Elektron. Nauchn.-Tekh. Zh., 2018, no. 11, pp. 86–92. http://www.viam-works.ru. Accessed January 15, 2020. https://doi.org/10.18577/2307-6046-2018-0-11-86-9210.18577/2307-6046-2018-0-11-86-92 ↗
9. Demidov, A.A., Kosarina, E.I., Mikhailova, N.A., and Turbin, E.M., Certification of radiographic films, Sb. dokl. X Vseross. Konf. “TestMat. Osnovnye tendentsii, napravleniya i perspektivy razvitiya metodov nerazrushayuschego kontrolya v aerokosmicheskoi otrasli” (Proc. All-Russ. Conf. “TestMat. Main Trends, Directions, and Prospects of Development of Nondestructive Testing Methods in Aerospace Industry”), Moscow: VIAM, 2018, pp. 56–64.
10. Gnedin, M.M. and Shablov, S.V., Radiographic testing. Requirements for the choice of radiographic film, V Mire NK, 2019, no. 2, pp. 14–18.10.12737/article_5ca30fa574b459.73938034 ↗
11. Kosarina, E.I., Krupnina, O.A., and Stepanov, A.V., Radiatsionnye metody nerazrushayuschego kontrolya (Radiation Methods of Nondestructive Testing—A Lecture Course), St. Petersburg: Sven, 2019.
12. Dobromyslov, V.A., Radiatsionnye metody nerazrushayuschego kontrolya (Radiation Methods of Nondestructive Testing), Moscow: Mashinostroenie, 1999.
13. Shtan’, A.S., Rumyantsev, S.V., and Gol’tsev, V.A., Spravochnik po radiatsionnim metodam kontrolya (Handbook on Radiation Testing Methods), Moscow: Atomizdat, 1983.
14. Selwyn, E.W.H., Phot. J., 1939, vol. 79. p. 513.
15. Draper, N. and Smith, G., Applied Regression Analysis, Chichester: Wiley, 1998.10.1002/9781118625590 ↗
16. Kalman, R.E., Falb, P.L., and Arbib, M.A., Topics in Mathematical System Theory, McGraw-Hill, 1969.
17. Moiseev, N.N., Matematicheskie zadachi sistemnogo analiza/Uchebnoe posobie (Mathematical Problems of System Analysis: A Handbook), Moscow: LIBROKOM, 2012, 2nd ed.