journal article·2000-07

Compensation for spurious signals due to misalignment of magnetic axes of a differential magnetic-modulation transducer. II. Theory

V. I. Pudov, S. V. Zhakov

Publisher page

Abstract

Calculations of the compensating field as functions of operating parameters of a compensating element based on the model of axially symmetrical distribution of surface magnetic charges are discussed. The efficiency of the compensation for spurious signals due to the misalignment of magnetic axes of a differential magnetic-modulation transducer and the transverse component of the terrestrial magnetic field is strongly affected by the selection of the optimal length of the compensating element, its diameter, shape, separation from the magnetically sensitive element, and other factors.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Diverse Industrial Engineering Technologies · Electric Power Systems and Control · Sensor Technology and Measurement Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. Afanas’ev, Yu.V.,Ferrozondy (Ferromagnetic Probes), Leningrad: Energiya, 1969.
2. Efremov, V.F. and Lyulik, V.P.,Metody kompensatsii apparaturnoi pogreshnosti differentsial’ nogo ferrozondovogo magnitometra. Geofizicheskaya apparatura (Methods of Compensation for Instrumental Errors of Differential Ferromagnetic-Probe Magnetometer: Geophysical Instruments), Leningrad: Nedra, issue no. 43, pp. 26–34.
3. Afanas’ev, Yu.V.,Ferrozondovye pribory (Instruments with Ferromagnetic Probes), Leningrad: Energoatomizdat, 1986.
4. Reutov, Yu.Ya. and Pudov, V.I., Compensation for Spurious Signals from a Differential Ferromagnetic Probe,Defektoskopiya, 1998, no. 2, pp. 18–22.
5. Pudov, V.I., Reutov, Yu.Ya., and Kulikov, V.A., Device for Localizing a Foreign Ferromagnetic Body in the Volumes of Eye and Socket, Russian Federation Patent no. 2090137,Byull. Izobr., 1997, no. 26, p. 285.
6. Pudov, V.I., Balancing Differential Transducer of Gradient Meter,Defektoskopiya, 1997, no. 11, pp. 54–57.
7. Pudov, V.I., Compensation for Spurious Signal due to Misalignment of Magnetic Axes of Differential Magnetic-Modulation Transducer. Part I,Defektoskopiya, 2000, no. 4, pp. 18–27.
8. Raevskii, E.I., Zhakov, S.V., Gass, V.G., and Korobeinikov, A.Yu., Use of Magnetically Soft Ferromagnets in Optimization of Systems of Permanent Magnets,Elektrotekhnika, 1995, no. 6, pp. 5–8.
9. Pudov, V.I., Compensation for Spurious Signal due to Misalignment of Magnetic Axes of Differential Magnetic-Modulation Transducer. Experiment,Defektoskopiya, 2000, no. 4, pp. 28–36.
10. Feldkeller, R.,Stuttgarter Arbeitsgemeinschaft. Schriften der Deutschen Akademie der Luftfahrtforschung, 1943, vol. 42, H. 1067/43 g.
11. Vedenev, M.A., Drozhzhina, V.I., and Friedmann, L.A., Design Calculations of Ferromagnetic Probes,Sbornik Trudov Inst. Fiz. Met. Akad. Nauk SSSR, Sverdlovsk, 1965, no. 24, pp. 110–125.
12. Osborn, J.A.,Phys. Rev., 1945, vol. 67, nos. 11-12, p. 351.10.1103/PhysRev.67.351 ↗
13. Chechernikov, V.I.,Magnitnye izmereniya (Magnetic Measurements), Moscow: Mos. Gos. Univ., 1963.
14. Postoyannye magnity. Spravochnik (Permanent Magnets. Reference Book), Pyatin, Yu. M., Ed., Moscow: Energiya, 1980.