Selecting parameters of discrete scanning systems for digital X-ray imaging
Source abstract
Abstract
For discrete scanning systems of digital X-ray imaging that contain an array of detectors, optimum values of the aperture length for each detector in the array and the step of discrete displacement (scanning) of a tested object are found. The determined values ensure the maximum resolution of such systems in the scanning direction for a given testing performance.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Digital Radiography and Breast Imaging · Advanced X-ray and CT Imaging · Radiation Detection and Scintillator Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. Klyuev, V.V. and Sosnin, F.R., Modern Radiation Systems for Nondestructive Testing, Defektoskopiya, 1993, no. 1, pp. 65–71.
2. Klyuev, V.V. and Sosnin, State-of-the-Art Digital X-ray Examination Equipment, Defektoskopiya, 1999, no. 4, pp. 56–66.
3. Sosnin, F.R., Modern Methods and Tools for Digital X-ray Radiography: A Review, Zavod. Lab., 1994, vol. 60, no. 6, pp. 28–34.
4. Baru, S.E., Safe X-Ray Analysis, Nauka v Rossii, 1997, no. 4, pp. 12–16.
5. Belova, I.B. and Kitaev, V.M., Digital Technologies for Producing X-ray Diffraction Images: Formation Principles and Types (Literature Review), Med. Vizualiz., 2000, no. 1, pp. 33–40.
6. Nedavnii, O.I. and Udod, V.A., Digital X-ray Radiographic Systems Today-State of the Art (A Review), Defektoskopiya, 2001, no. 8, pp. 62–82 [Rus. J. of Nondestructive Testing (Engl. Transl.), 2001, vol. 37, no. 8, p. 576].10.1023/A:1014219102481 ↗
7. Halmshaw, R., An Analysis of the Performance of X-ray Television-Fluoroscopic Equipment in Weld Inspection, Mater. Eval., 1987, vol. 45, no. 11, pp. 1289–1302.
8. Berdyakov, G.I., Rtishcheva, G.M., and Kokuev, A.N., Construction and Application of Digital X-ray Apparatuses for lungs Diagnostics, Med. Techn., 1998, no. 5, pp. 33–40.
9. Yaffe, M.J. and Rowlands, J.A., X-ray Detectors for Digital Radiography: Review, Phys. Med. Biol., 1997, vol. 42, no. 1, pp. 1–39.10.1088/0031-9155/42/1/001 ↗
10. Gusev, E.A., Firstov, V.G., Petushkov, A.A., et al., Scanning X-ray Introscope with One-Dimensional Matrix Transducer Based on Silicon Radiation Detectors, Defektoskopiya, 1989, no. 7, pp. 38–42.
11. Nedavnii, O.I. and Udod, V.A., Mathematical Model of Multichannel Scanning Systems for Digital Radiography, Kontrol’. Diagnost., 2002, no. 2, pp. 27–33.
12. Pratt, W., Digital Image Processing, New York: Wiley, 1978. Translated under the title Tsifrovaya obrabotka izobrazhenii, Moscow: Mir, 1982.
13. Ryftin, Ya.A., Televizionnaya sistema. Teoriya (Television System: A Theory), Moscow: Sov. Radio, 1967.
14. Gurvich, A.M., Quantum Fluctuations and Their Role in the Applied X-ray Fluoroscopy, Izv. Akad. Nauk SSSR, ser. Fiz., 1981, vol. 46, no. 5, pp. 964–969.
15. Udod, V.A., Correct Formal Description of the Foucault Criterion for Spatial Resolution, Obozr. Prikl. Promyshl. Matem., 2002, vol. 9, no. 2, pp. 473–474.
16. Udod, V.A., Optimization of the Parameter of a One-Dimensional Image Filter Using the Maximum-Resolution Criterion, Avtometriya, 2005, vol. 41, no. 1, pp. 29–42.
17. Udod, V.A., Estimation of the Resolution of Imaging Systems with Digitization of Images over a Rectangular Scanning Pattern and Their Subsequent Interpolation, Avtometriya, 2002, vol. 38, no. 4, pp. 66–73.
18. Gorbunov, V.I., Zav’yalkin, F.M., Solodushkin, V.I., and Udod, V.A., The Choice of Parameters of Radiometric Systems with Discrete Scanning of the Radiation Field, Avtometriya, 1987, no. 4, pp. 21–27.
19. Fikhtengol’ts, G.M., Kurs differentsial’nogo i integral’nogo ischisleniya (The Course of Differential and Integral Calculus), Moscow: Nauka, 1970, vol. 1.