journal article·2000-03

Reduction in the service life due to an overload test of a metallic structure operated under corrosive conditions

G. V. Petrov

Publisher page

Abstract

The effect of an overloading test on the remaining service life of a metallic structure exposed to corrosion is discussed. Conditions of destruction during such tests have been determined. The reduction in the service life as a result of such tests is quite considerable, but, if an overloading test does not lead to destruction, the reduction in the service life is small.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Material Properties and Failure Mechanisms · Engineering Diagnostics and Reliability · Material Properties and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (1)

Show source-provided references
1. Petrov, V.A., On Overloading Tests,Defektoskopiya, 1997, no. 3, pp. 92–98.