journal article·2007-04

An IMPOC-1BM pulsed magnetic production-line monitor

V. F. Matyuk, M. N. Delendik, V. B. Kratirov, A. A. Osipov, D. A. Pinchukov, H. Hartmann, H. Reihelt, R. Schmidt

Publisher page

Abstract

An IMPOC-1BM setup for the nondestructive testing of the mechanical properties of rolled steel sheets no thicker than 3 mm on a production line is described. The setup operates at a velocity of a moving sheet of up to 10 m/s and with a 2-m distance between the test points. The results of its laboratory and production tests are presented.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Magnetic Properties and Applications · Non-Destructive Testing Techniques · Microstructure and Mechanical Properties of Steels

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (8)

Show source-provided references
1. Matyuk, V.F., Goncharenko, S.A., Hartmann, H., and Reichelt, H., Modern State of Nondestructive Testing of Mechanical Properties and Stamping Ability of Steel Sheets in a Production Line, Defektoskopiya, 2003, no. 5, pp. 19–60 [Rus. J. of Nondestructive Testing (Engl. Transl.), 2003, vol. 39, no. 5., p. 347].10.1023/B:RUNT.0000011264.99280.de ↗
2. Matyuk, V.F. Pulsed Magnetic Testing of Strength Characteristics of Ferromagnetic Products, Vest. Nat. Akad. Nauk Belarusi, Ser. Fiz.-Tekh., 1998, no. 4, pp. 114–118.
3. Mel’gui, M.A. and Matyuk, V.F. IMPOC-1 Pulsed Magnetic Production-Line Controller IMPOC-1, Defektoskopiya, 1982, no. 9, pp. 62–66.
4. Matyuk, V.F., Improving the Parameters of Tools for Pulsed Magnetic Testing of Moving Rolled Sheets, Defektoskopiya, 1989, no. 9, pp. 52–58.
5. Mel’gui, M.A., Matyuk, V.F., and Tsukerman, V.L., IMPOC-2 Instrument for Testing Mechanical Properties of Rolled Steel Sheets Moving on a Production Line, Tekh. Diagnost. Nerazrush. Kontrol’, 1994, no. 2, pp. 62–66.
6. Matyuk, V.F. and Tsukerman, V.L., IMPOC-1A Pulsed Magnetic Production-Line Checker, Defektoskopiya, 1992, no. 4, pp. 38–43.10.1134/S106183090704002X ↗
7. Matyuk, V.F. and Osipov, A.A., Pulsed Magnetic Method for Testing Separately Moving Sheets on a Production Line, Defektoskopiya, 1995, no. 6, pp. 56–62.
8. Matyuk, V. and Strelyukhin, A., Influence of a Mode of Local Pulse Magnetization on the Magnitude of Residual Magnetization of a Ferromagnet at the Constant Form of Magnetizing Pulses, Proc. Int. Conf. “Computer Methods and Inverse Problems in Nondestructive Testing and Diagnostics”, CM NDT-95, Minsk, 1995, pp. 63–66.