Abstract

A brief review of leak hunting methods is presented as well as some estimates of sensitivity thresholds and other properties for different methods. It is shown that gas-analysis methods are of particular interest due to their high sensitivity and universality. The main problematic properties of these methods such as, mainly, their bulkiness and instantaneous nature of testing are formulated. Taking the above into account, the use of solid-state sensors is justified in designing gas-analysis leak-hunting systems, including systems that operate alongside technological equipment and use fumes of working substances inside the equipment as tracer leak-hunting gases. A sensor operating on surface acoustic waves (SAW-sensor) is considered as one of the most promising sensors.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Acoustic Wave Resonator Technologies · Advanced Chemical Sensor Technologies · Mechanical and Optical Resonators

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (21)

Show source-provided references
1. GOST (Russian Standard) 24054-80. Machine building and instrument making articles. Hermeticity testing (with Correction 1).
2. Evlampiev, A.I., Popov, E.D., Sazhin S.G., Murav’eva, L.D., Dobrotin, S.A., Polovinkin, A.V., and Kondrat’ev, Yu.A., Kontrol’ germetichnosti. Nerazrushayushchii kontrol'. Spravochnik. V 8 t. (Hermeticity Control. Nondestructive Testing: A Handbook, 8 vols.), Klyuev, V.V., Ed., vol. 2, book1.
3. Burlaenko, N.A., Maslennikov, A.B., and Sazhin, S.G., Characteristics of piezoresonance gas-analysis sensor and possible ways of correction for solving hermeticity control problems, Defektoskopiya, 1996, no. 4, pp. 11–14.
4. Sazhin, S.G., Soborover, E.I., and Tokarev, S.V., Sensor methods of ammonia inspection, Russ. J. Nondstr. Test., 2003, vol. 39, no. 10, pp. 791–806.10.1023/B:RUNT.0000020251.56686.a5 ↗
5. Sazhin, S.G., Soborover, E.I., and Bessonov, S.G., Developing sensor gauges for freon-134a for automation of leak hunting in technological equipment, Tr. Nizhny Novgorod State Tech. Univ. Khim. Pishch. Prom-st.: Sovrem. Zadachi Tekh. Tekhn. Avtom. Ekon., Nizhny Novgorod, 2004, vol. 45, pp. 177–180.
6. Soborover, E.I. and Zubkov, I.L., A high-efficiency planar-waveguide design of optical chemical sensor for gasanalysis, In: DATCHIK-2002. Datchiki i preobrazovateli informatsii sistem izmereniya, kontrolya i upravleniya. Sb. mater. XIV nauchn.-tekhn. konf., (DETECTOR-2002. Detectors and Transducers of Information in Measurement, Control, and Management Systems. Proc. XIV Sci. Tech. Conf.) Moscow: Moscow State Inst. Electron. Math., 2002.
7. Soborover, E.I. and Bakulin, P.A., Studying the sensor effect in a planar-waveguide optical chemical gas sensor, Datchiki Sist., 2000, no. 3, pp. 11–17.
8. Burlaenko, N.A. and Maslennikov, A.B., Piezoresonance ammonium sensor and its static characteristics, Defektoskopiya, 1996, no. 4, pp. 23–26.
9. Malov, V.V., P’ezorezonansnye datchiki. 2-e izd., pererab. i dop. (Piezoresonance Sensors), Moscow: Energoatomizdat, 1989, 2nd ed.
10. Benes, E., Groshl, M., Seifert, F., and Poh, A., Comparison between BAW and SAW sensor principles, IEEE Int. Freq. Control Symp., 1997.
11. Gorgashin, N.M., Surveillance of ammonium refrigerating plants, Bezop. Tr. Prom-sti., 1999, no. 1, pp. 13–15.
12. Wohltjen, H. and Dessy, R., Surface acoustic wave probe for chemical analysis. II. Gas chromatography detector, Anal. Chem., 1979, vol. 51, no. 9, pp. 1465–1470.10.1021/ac50045a025 ↗
13. Acoustic Surface Waves, Oliner, A.A., Ed., Berlin-Heidelberg-New York: Springer-Verlag, 1981.
14. Liron, Z., Kanshansk, N., Frishman, G., Caplan, D., and Greenblatt, J., The polymercoated SAW sensor as a gravimetric sensor, Anal. Chem, 1997, vol. 69, no. 14, pp. 2848–2854.10.1021/ac9611935 ↗
15. Snow, A. and Wohltjen, H., Poly(ethylene maleate)-cyclopentadiene: a model reactive polymer vapor system for evaluation of a SAW microsensor, Anal. Chem., 1984, v. 56, p. 1411–1416.10.1021/ac00272a047 ↗
16. Aleinikov, A.N., Vershinin, N.N., and Kochan, Ya.L., Gas sensors. Determining the content of ammonium in air, Tekh. Mashinostr., 1997, no. 2, p. 45.
17. Wohltjen, H. and Dessy, R., Surface acoustic wave probe for chemical analysis. I. Introduction and instrument description, Anal. Chem, 1979, vol. 51, no. 9, p. 1458.10.1021/ac50045a024 ↗
18. Kankare, J., Loikas, K., and Salomaki, M., Method for measuring the losses and loading of a quartz crystal microbalance, Anal. Chem., 2006, vol. 78, no. 6, pp. 1875–1882.10.1021/ac051908g ↗
19. Gundelach, V.G., Entwicklungstrends von Sensoren in der Chemischen Technik, Chem. Ing. Techn., 1987, vol. 59, no. 12, pp. 927–936.10.1002/cite.330591206 ↗
20. Sapper, A., Wegener, J., and Janshoff, A., Cell motility probed by noise analysis of thickness shear mode resonators, Anal. Chem., 2006, vol. 78, no. 14, pp. 5184–5191.10.1021/ac060094g ↗
21. Kuznetsov, L.A., Pripachkin, V.I., Milonov, M.V., and Milovanov, S.V., Digital measurement facility for masssensitive detectors, Datchiki Sist., 2002, no. 3, p. 36.