Improving the detectability of cracks during flow inspection by 3D tomography
Source abstract
Abstract
The advantages of X-ray computer tomography over industrial radiography are described as applied to the problem of detecting arbitrarily oriented cracks. The approximate Feldkamp projection algorithm and the approximate reverse-projection algorithm with double differentiation filtration (RPDDF) are considered and methods for improving their accuracy are proposed. The possibility of increasing the reconstruction rate by using the pipelined algorithm and the spiral trajectory of a source is shown.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging · Electrical and Bioimpedance Tomography
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (11)
Show source-provided references
1. Kim, J. and Liaw, P.K., The nondestructive evaluation of advanced ceramics and ceramic-matrix composites, JOM, 1998, vol. 50, no. 11.
2. Kirillov, A.A., On one Gel’fand’s problem, Dokl. AN SSSR, 1961, vol. 137, no. 2, pp. 276–277.
3. Tuy, H.K., An inversion formula for cone-beam reconstruction, SIAM J. Appl. Math., 1983, vol. 43, no. 3, pp. 546–552.10.1137/0143035 ↗
4. Smith, B.D., Cone-beam tomography: recent advances and tutorial review, Optical Engineering, 1990, vol. 29, no. 5, pp. 524–534.10.1117/12.55621 ↗
5. Feldkamp, L.A., Devis, L.C., and Kress, J.W., Practical cone-beam algorithm, J. Opt. Soc. Am. Al., 1984, pp. 612–619.
6. Katsevich, A., Improved exact FBP algorithm for spiral CT, Adv. Appl. Math., 2004, vol. 32, pp. 681–697.10.1016/S0196-8858(03)00099-X ↗
7. Grass, M., Köhler, T., and Proksa, T., 3D cone-beam CT reconstruction for circular trajectories, Physics in Medicine and Biology, 2000, vol. 45, pp. 329–348.10.1088/0031-9155/45/2/306 ↗
8. Wang, G., Lin, T.H., Cheng, P., and Shinozaki, D.M., A general cone-beam reconstruction algorithm, IEEE Trans. Med. Image, 1993, vol. MI-12, pp. 486–496.10.1109/42.241876 ↗
9. Yan, X. and Leahy, R.M., Cone-beam tomography with circular, elliptical and spiral orbits, Physics in Medicine and Biology, 1992, vol. 37, pp. 493–506.10.1088/0031-9155/37/3/001 ↗
10. Karikh, V.P., Computational efficiency of 3D tomography pipelined algorithm, Avtometriya, 2008, vol. 44, no. 1, pp. 92–99.
11. Vainberg, E.I., Kazak, I.A., and Faingoiz, M.L., X-ray computational tomography involving reverse projection method with double differentiation filtration, Defektoskopiya, 1985, no. 2, pp. 11–16.