A mathematical two-pole point magnetization model for evaluating the thicknesses of nonmagnetic coatings
Source abstract
Abstract
Analytical expressions for the dependence of the measured magnetic field on the thickness of a nonmagnetic coating or gap between a transducer and magnetized plate are obtained. The magnetization values of a uniform infinite plate by point poles with the same (or different) signs are compared.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Induction Heating and Inverter Technology · Non-Destructive Testing Techniques · Magnetic Properties and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (5)
Show source-provided references
1. Lukhvich, A.A. and Bulatov, O.V., The capabilities of the magnetodynamic method for testing thicknesses of nickel coatings on bases with different magnetic properties, Russ. J. Nondestr. Test., 2010, no. 10, p. 768.
2. Kostin, V.N. and Vasilenko, O.N., Local measurement of the coercive-return induction in the presence of a gap in the transducer-object combined circuit, Russ. J. Nondestr. Test., 2012, no. 7, p. 391.
3. Kostin, V.N. and Vasilenko, O.N., On new possibilities for making local measurements of the coercive force of ferromagnetic objects, Russ. J. Nondestr. Test., 2012, no. 7, p. 401.
4. Jackson, J.D., Classical Electrodynamics, London: Wiley, 1962.
5. Pechenkov, A.N., Shcherbinin, V.E., and Smorodinskii, Ya.G., An analytical model of the point magnetization of a thin ferromagnetic plate, Russ. J. Nondestr. Test., 2011, no. 12, p. 796.