journal article·2009-01

Inspection of the adhesion strength of an electrical insulating coating with the surface of anisotropic steel

L. S. Karenina, G. S. Korzunin, R. B. Puzhevich, A. I. Pyatygin

Publisher page

Abstract

It has been shown that the thickness of a coating does not affect its adhesion strength with metal. As the metal thickness increases, for each 0.01 mm, the critical diameter of bending of a specimen at which the coating exfoliates increases by 1 mm. The presence of chromium in the electrical insulating coating causes its adhesion properties to decrease. The quality of the ground layer is a very important characteristic affecting the adhesion strength between the coating and metal.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Material Properties and Applications · Material Properties and Failure Mechanisms · Engineering Diagnostics and Reliability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (6)

Show source-provided references
1. GOST (State Standard) 21427.1-83: Cold-Rolled Anisotropic Thin Sheet Electric Steel.
2. Specifications of ABB (USA).
3. SYEMEMS. Company Standard TUN 901-170-en, Issue 2006-09.
4. State Standard of PRC, GB/T-2522-88.
5. Puzhevich, R.B. and Korzunin, G.S., Inspection of Quality of Insulating Coating on Electric Steel, Defektoskopiya, 2006, no. 7, pp. 65–72 [Rus. J. Nondestruct. Test. (Engl. Transl.), 2006, vol. 42, no. 7, pp. 468–473].10.1134/S1061830906070060 ↗