Ultrasonic testing on a singly reflected beam using sparse antenna arrays and 3D echo-signal processing
Source abstract
Abstract
Testing of welded joints in the main shutoff valves (MSVs) of the first circuit of a ВВЭР-440 reactor plant is impeded due to the high structural-noise level and the necessity of using pulses that are singly reflected from the tilted bottom of a branch pipe. Testing on a longitudinal wave leads to the appearance of false reflections, which are formed by pulses at a transverse wave, in the reconstructed image. Since the amplitude of false reflections can be commensurable with the amplitude of reflections that were obtained at longitudinal waves, the analysis of such images may be hampered. To increase the quality of an image, it is proposed to record echo signals using sparse antenna arrays and use 3D processing of echo signals. Numerical and model experiments showed that this approach increases the frontal resolution in the additional plane by several times and reduces the amplitude of false reflections, thus making it possible to increase the sensitivity and reliability of expert ultrasonic testing of the principal shutoff valve.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Engineering Diagnostics and Reliability · Ultrasonics and Acoustic Wave Propagation · Material Properties and Failure Mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. Bazulin, A.E., Bazulin, E.G., Gordeev, Yu.L., Kostylov, A.G., Tikhonov, D.S., and Shtern, A.M., AVGUR mobile measuring systems for automatic ultrasonic testing, V Mire Nerazrushayushchego Kontrolya, 2010, no. 1(47), pp. 16–23.
2. Badalyan, V.G. and Bazulin, E.G., Digital reconstruction of scatterer images by the method of projection in the spectral space, Akust. Zh., 1988, vol. 34, no. 2, pp. 222–231.
3. Bazulin, A.E., Bazulin, E.G., Vopilkin, A.Kh., Kokolev, S.A., Romashkin, S.V., and Tikhonov, D.S., Application of 3D coherent processing in ultrasonic testing, Russ. J. Nondestr. Test., 2014, vol. 50, no. 2, pp. 92–108. DOI: 10.1134/S1061830914020028.10.1134/S1061830914020028 ↗
4. Defectoscope A1550 IntroVisor. http://www.acsys.ru/production/detail/a1550-introvisor/ (date of application, March 27, 2015).
5. Kovalev, A.V., Kozlov, V.N., Samokrutov, A.A., Shevaldykin, V.G., and Yakovlev, N.N., Pulse echo in concrete monitoring: interference and spectral selection, Russ. J. Nondestr. Test., 1990, vol. 26, no. 2, pp. 110–118.
6. Jobst, M. and Connolly G.D., Demonstration of the application of the total focusing method to the inspection of steel welds, Proc. 10th European Conf. on Non-Destr. Test., Moscow, 2010.
7. http://www.extende.com/(date of application, March 27, 2015).
8. Born, M. and Vol’f, E., Osnovy optiki (Fundamentals of Optics), Moscow: Nauka, 1973.
9. Bazulin, E.G., The possibility of using the maximum-entropy method in ultrasonic nondestructive testing for increasing the resolution of echo signals, Acoust. Phys., 2013, no. 2, pp. 235–254. DOI: 10.1134/S1063771013020024.
10. Samokrutov, A.A. and Shevaldykin, V.G., On the possibility of evaluating the character of a metal discontinuity flaw using an ultrasonic tomograph with digital focusing of the antenna array, Kontr. Diagnost., 2011, no. 10, pp. 63–70.
11. Bazulin, E.G., Vopilkin, A.Kh., and Tikhonov, D.S., Increasing the reliability of ultrasonic testing. Part 2. Increasing the signal-to-noise ratio, Kontr. Diagnost., 2015, no. 9, pp. 10–27.10.14489/td.2015.09.pp.010-027 ↗
12. Bazulin, E.G. and Kokolev, S.A., Increasing the signal-to-noise ratio in ultrasonic testing of repair welds using the technology of thinned antenna arrays, Russ. J. Nondestr. Test., 2013, vol. 49, no. 5, pp. 283–293. DOI: 10.1134/S1061830913050021.10.1134/S1061830913050021 ↗