A mathematical model of multichannel continuously scanning systems for digital X-ray analysis
Source abstract
Abstract
A mathematical model of continuously scanning systems for digital X-ray analysis is developed. The systems contain a linear array of detectors that can be used not only in systems of radiation sources with an anisotropic angular distribution and a nonuniform distribution of the quantum yield over the focal spot but also in systems of detectors with nonuniform spatial sensitivity to incident radiation. The systems also make it possible to normalize the records of the radiation image of a tested object and perform digital filtering of the results.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Radiation Detection and Scintillator Technologies · Advanced Energy Technologies and Civil Engineering Innovations · Digital Radiography and Breast Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. Klyuev, V.V. and Sosnin, F.R., State-of-the-Art Radiation Systems of Nondestructive Testing, Defektoskopiya, 1993, no. 1, pp. 65–71.
2. Klyuev, V.V. and Sosnin, F.R., Present-Day State of Digital X-Ray Engineering, Defektoskopiya, 1999, no. 4, pp. 56–66.
3. Sosnin, F.R., State-of-the-Art Methods and Tools of Digital X-Ray Engineering (Review), Zavod. Lab., 1994
4. Baru, S.E., Safe X-Ray Engineering, Nauka v Rossii, 1997, no. 4, pp. 12–16.
5. Belova, I.B. and Kitaev, V.M., Digital Technologies for Obtaining X-Ray Diffraction Images: Principles of Formation and Types (Literature Review), Med. Vizulizat., 2000, no. 1, pp. 33–40.
6. Nedavnii, O.I. and Udod, V.A., State-of-the-Art Digital Radiographic Systems (Review), Defektoskopiya, 2001, no. 8, pp. 62–82 [Rus. J. of Nondestructive Testing (Engl. Transl.), 2001, vol. 37, no. 8, p. 576].
7. Halmshaw, R., An Analysis of the Performance of X-ray Television-Fluoroscopy Equipment in Weld Inspection, Mater. Eval., 1987, vol. 45, no. 11, pp. 1289–1302.
8. Berdyakov, G.I., Rtishcheva, G.M., and Kokuev, A.N., The Design and Application of Digital X-Ray Instruments for Lungs Examination, Med. Tekh., 1998, no. 5, pp. 33–40.
9. Yaffe, M.J. and Rowlands, J.A., X-Ray Detectors for Digital Radiography. Review, Phys. Med. and Biol., 1997, vol. 42, no. 1, pp. 1–39.10.1088/0031-9155/42/1/001 ↗
10. Gusev, E.A., Firstov, V.G., Petushkov, A.A., et al., Scanning X-Ray Introscope with One-Dimensional Matrix Probe Based on Silicon Radiation Detectors, Defektoskopiya, 1989, no. 7, pp. 38–42.
11. Yaroslavskii, L.P., Vvedenie v tsifrovuyu obrabotku izobrazhenii (Introduction to Digital Image Processing), Moscow: Sovetskoe Radio, 1979.
12. Pratt, W.K., Digital Image Processing, New York: Wiley, 1978. Translated under the title Tsifrovaya obrabotka izobrazhenii, Moscow: Mir, 1982.
13. Udod, V.A., Multichannel Radiometric Testing Systems with Gray Visualization of Shadow Radiation Images, Extended Abstract of Cand. Sci. Dissertation, Tomsk, 1990.
14. Nedavnii, O.I., Maksimenko, B.V., Osipov, S.P., and Udod, V.A., Multichannel Radiometric Testing Systems with Gray Visualization of Shadow Radiation Images: 1. Mathematical Model, Defektoskopiya, 1993, no. 4, pp. 70–74.
15. Nedavnii, O.I. and Udod, V.A., Mathematical Model of Multichannel Scanning Systems of Digital Radiography, Kontrol’. Diagnostika, 2002, no. 2, pp. 27–33.