Increasing the Reliability of Magnetic-Particle Testing by Means of a УМЛК-10 Automated Unit for Magnetic Fluorescent-Penetrant Inspection of Pipe End Faces

A. S. Bakunov, V. P. Kurozaev, D. A. Kudryavtsev, V. K. Bronnikov, V. G. Kravchenko

Publisher page

Abstract

The design of an automated unit for magnetic fluorescent-penetrant inspection of end faces of pipes in in-line production is described. The structural diagram of the unit is given. The problem of measuring the magnetic field induced by the unit is considered. A procedure for the preparation of a reference specimen required for checking the work capability of the unit is described.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Non-Destructive Testing Techniques · Engineering Diagnostics and Reliability · Industrial Engineering and Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (7)

Show source-provided references
1. Nerazrushayushchii kontrol' i diagnostika. Spravochnik (Nondestructive Testing and Diagnostics. Handbook), Kluev, V.V., Ed., Moscow: Mashinostroenie, 1995.
2. Moreira, E., Iwamoto, J., Godoy, J., Ferreira, S., Automatic End Inspection System by Magnetic Particle of Expanded Pipes Manufactured from UOE Process, Paper Summaries Book 2nd Pan-American Conf. for Nonde-structive Testing, Houston, Texas, USA, 2001, pp. 141–146.
3. Shelikhov, G.S., Magnitoporoshkovaya defektoskopiya detalei i uzlov (Magnetic-Particle Testing of Parts and Units), Moscow: Nauchno-tekhnicheskii tsentr "Ekspert", 1995.
4. Zagidulin, R.V., Muzhitskii, V.F., and Kurozaev, V.P., Calculation of Magnetostatic Field within an Internal Flaw and a Flaw of Inner Surface in a Ferromagnetic Plate: II. Magnetic Field of a Flaw in Air. Nonlinear Medium, Defektoskopiya, 1997, no. 1, pp. 55–62.
5. Zagidulin, R.V., Shcherbinin, V.E., Quality and Information Content of Classification Indications of Continuity Flaws. Quantity of Information on Flaw Parameters, Defektoskopiya, 1994, no. 12, pp. 56–69.
6. Muzhitskii, V.F. and Kudryavtsev, D.A., Some Problems in Determining the Optimum Sizes of Magnetizing Sys-tems Based on Permanent Magnets, Defektoskopiya, 2004, no. 2, pp. 67–75 [Russian J. of Nondestructive Testing (Engl. Transl.), 2004, vol. 40, no. 2, p. 124].
7. Shelikhov, G.S. and Glazkov, Yu.A., Principles of Checking Magnetic-Particle Flaw Detectors, Kontrol'. Diagnos-tika, 2003, no. 9, pp. 6–12.