Magnetic measurements of component thickness in structures composed of nonmagnetic coating and ferromagnetic base
Source abstract
Abstract
The paper describes a technique and an instrument for simultaneous absolute thickness measurements of components in structures composed of a nonmagnetic coating and a ferromagnetic base. The technique is based on measurements of the normal magnetic induction component of the secondary field at two points and comparison of these measurements with similar parameters of reference samples.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Induction Heating and Inverter Technology · Non-Destructive Testing Techniques · Magnetic Properties and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (4)
Show source-provided references
1. Karpov, V.I., Zatsepin, N.N., and Shaporov, B.D., Experimental Study of Some Electromagnetic Characteristics of Steel Corrosion Products,Defektoskopiya, 1980, no. 6, pp. 9–14.
2. Filippov, B.N., Glukhov, V.M., and Gorkunov, E.S., Modeling of Magnetic States in a Ferromagnetic Rod Magnetized in a Pass-Through Converter,Defektoskopiya, 1998, no. 7, pp. 50–59.
3. Mikheev, N.M., Optimal Dimensions of Attached Electromagnet of a Coercive Force Meter for Testing Quality of Thermal and Thermochemical Processing of Steel and Cast-Iron Works, inMagnitnye metody defektoskopii, analiza i izmerenii (Magnetic Methods of Flaw Detection, Analysis, and Measurements),Proc. of a Scientific-Technical Conference, Sverdlovsk, 1959.
4. Mel’gui, M.A. and Matyuk, V.F., Possibility Study of Insulating from Effect of Changes in the Width of Gap between Transducer and Tested Material in Pulsed Magnetic Measurements,Defektoskopiya, 1981, no. 6, pp. 74–79.