Estimating the possibility of the magnetic detection of microflaws in weld seams of longitudinal electric-welded pipes manufactured by butt high-frequency welding
Source abstract
Abstract
Fragments of longitudinal electric-welded pipes were inspected in the state after their manufacturing. The presence of flaws, like surface cracks with openings of nearly 10 μm, were detected by means of optical testing in the zone of a weld seam. It was shown that such cracks can be easily detected at the УMД-101M magnetic nondestructive testing station.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Material Properties and Failure Mechanisms · Engineering Diagnostics and Reliability · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (2)
Show source-provided references
1. Dorofeev, A.L. and Kazamanov, Yu.G., Elektromagnitnaya Defektoskopiya (Electromagnetic Flaw Detection), Moscow: Mashinostroenie, 1980.
2. Shleenkov, A.S., Bulychev, O.A., and Shleenkov, S.A., The УMД-101M Station for Automated Bulk Magnetic Nondestructive Testing of Quality of Electric-Welded Pipes, Defektoskopiya, 2008, no. 8, pp. 76–82 [Rus. J. Nondestr. Test., (Engl. Transl.), 2008, vol. 44, no. 8, pp. 574–578].10.1134/S106183090808010X ↗