journal article·2025-01

X-ray Fluorescence Methods of Multilayer Coating Thickness Measurements on Satellite Launch Vehicle Components

Raju G, Rohit Kumar Gupta, Ashok M

Publisher page

Abstract

Abstract Surface treatment technology has widened its horizon over various applications; from metal surfaces to modern high-tech polyurethanes Metallic hardware of satellite launch vehicles is applied with single and multilayer thermal barriers and other special metallic coatings to meet harsh environments and unflinching functional requirements. Tactile nondestructive evaluation and metrology methods are generally used to assess the thickness of these coatings. However, these cumulative methods cannot be relied upon for the individual layer thickness of multilayer coated components. The X-ray fluorescence method has emerged as a tool for the qualitative and quantitative determination of the layer thicknesses irrespective of single or multilayer coating. In addition to the Fundamental Parameter mode with and without the calibration standard, this study experiments with a new empirical mode with two calibration standards. It also investigates the consistency of X-ray fluorescence measurements and the effects of infinite thickness and impurities on the coating thickness. As the X-ray fluorescence assessment of the underneath coatings shows large deviations, a simulation study is discussed to determine the correction factor to be applied at the specified thickness ranges. This study highlights the comparative advantages of the X-ray fluorescence method over the other conventional methods. This study also proves that the empirical mode is a promising X-ray fluorescence method for a better assessment of intermediate and undercoat thickness on multilayer coated metallic substrate in a single exposure.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Nuclear Physics and Applications · X-ray Spectroscopy and Fluorescence Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. Liu, S., Shohji, I., Iioka, M., Hashimoto, A., Hirohashi, J., and Wake, T., Micro-brazing of stainless steel using Ni-P alloy plating, Appl. Sci., 2019, vol. 9, no. 6, p. 1094. https://doi.org/10.3390/app906109410.3390/app9061094 ↗
2. Metal plating processes and methods of measuring surface hardness and thickness of coatings, Technical Report: TR-#105(100-97), Balseal Eng. Co., Inc., 2003. https://www.balseal.com/wp-content/uploads/2019/03/plating_thickness_and_hardness_measurementTR_105.pdf
3. Ohgaki, M., Methods of fluorescent X-ray analysis for measuring the thickness of multilayered plating, Tech. Mag. Electron Microscope Anal. Instrum., 2019, vol. 13, pp. 47–59.
4. Giurlani, W., Berretti, E., and Innocenti, M., Measuring the thickness of metal coatings: a review of the methods, Coatings, 2020, vol. 10, no. 12, p. 1211. https://doi.org/10.3390/coatings1012121110.3390/coatings10121211 ↗
5. Cruz, J.P.N., Garzon, C.M., and Recco, A.A.C., SEM-EDS coating thickness assessment: an insight into the accuracy of Monte Carlo simulations carried out for TiN coatings using three different freeware graphical user interface, Microsc. Microanal., 2021, vol. 27 (Suppl 1), pp. 895–896. https://doi.org/10.1017/S143192762100895310.1017/S1431927621008953 ↗
6. Szklarska, M., Dercz, G., Smołka, A., Popczyk, M., and Łosiewicz, B., A coulometric method by local anodic dissolution for measuring the thickness of Ni/Cu multi-layer electrocoatings, Solid State Phenom., 2015, vol. 228, pp. 319–324. https://doi.org/10.4028/www.scientific.net/SSP.228.31910.4028/www.scientific.net/SSP.228.319 ↗
7. Arjhangmehr, A. and Mohammadzadeh, M., Beta-backscattering thickness-meter design and evaluation with fuzzy TOPSIS method, Nukleonika, 2014, vol. 59, pp. 53–59. https://doi.org/10.2478/nuka-2014-001110.2478/nuka-2014-0011 ↗
8. Antwerpen, K.D.G. and Clapera, R.S., Energy dispersive X-ray fluorescence: Measuring elements in solid and liquid matrices, Final Degree Project–Outgoing Erasmus Students, 2006.
9. Giurlani, W., Berretti, E., and Innocenti, M., Fluorescence spectroscopy: Monte Carlo simulations as an alternative to the use of standards, Coatings, 2019, vol. 9, no. 2, p. 79. https://doi.org/10.3390/coatings902007910.3390/coatings9020079 ↗
10. Kahraman, F., An investigation of the effect of heat treatment on surface roughness in machining by using statistical analysis, Iran. J. Sci. Technol. Trans. B Eng., 2010. https://www.researchgate.net/publication/228533843
11. Aliofkhazraei, M., Walsh, F.C., Zangari, G., Köçkar, H., Alper, M., Rizal, C., Magagnin, L., Protsenko, V., Arunachalam, R., Rezvanian, A., Moein, A., Assareh, S., and Allahyarzadeh, M.H., development of electrodeposited multilayer coatings: a review of fabrication, microstructure, properties and applications, Appl. Surf. Sci. Adv., 2021, vol. 6, p. 100141. https://doi.org/10.1016/j.apsadv.2021.10014110.1016/j.apsadv.2021.100141 ↗
12. Sekatskii, V.S. et al., Two-point calibration of coating thickness gauges: What needs to be considered to improve measurement accuracy, IOP Conf. Ser. Mater. Sci. Eng., 2019, vol. 537, p. 032068. https://doi.org/10.1088/1757-899X/537/3/03206810.1088/1757-899X/537/3/032068 ↗
13. Li, F., Ge, L., Tang, Z., Chen, Y., and Wang, J., Recent developments on XRF spectra evaluation, Appl. Spectrosc. Rev., 2019, pp. 1–25. https://doi.org/10.1080/05704928.2019.158071510.1080/05704928.2019.1580715 ↗
14. Tips & Tricks for the Collection of Quality Portable XRF Data, Portable Spectral Service, URL: https://www.portaspecs.com/tips-tricks-for-the-collection-of-quality-portable-xrf-data.
15. Martinuzzi, S., Giovani, C., Giurlani, W., Galvanetto, E., Calisi, N., Casale, M., Fontanesi, C., Ciattini, S., and Innocenti, M., A robust and cost-effective protocol to fabricate calibration standards for the thickness determination of metal coatings by XRF, Spectrochim. Acta Part B At. Spectrosc., 2021, p. 106255. https://doi.org/10.1016/j.sab.2021.10625510.1016/j.sab.2021.106255 ↗
16. Sitko, R., Quantitative X-ray fluorescence analysis of samples of less than ‘infinite thickness’: difficulties and possibilities, Spectrochim. Acta Part B At. Spectrosc., 2009, vol. 64, pp. 1161–1172. https://doi.org/10.1016/j.sab.2009.09.00510.1016/j.sab.2009.09.005 ↗
17. Lu, J., A matrix effect correction method for portable X-ray fluorescence data, Appl. Sci., 2022. URL: https://www.mdpi.com/journal/applsci.10.3390/app12020568 ↗
18. Zaimovic-Uzunovic, N., Lemes, S., Tomasevic, D., and Kacmarcik, J., Flatness measurement on a coordinate measuring machine, 5th Int. Conf. New Technol. Dev. Appl. (NT-2019) (2019), pp. 27–29.10.1007/978-3-030-18072-0_19 ↗
19. Rousseau, R.M., Detection limit and estimate of uncertainty of analytical XRF results, Rigaku J., 2001, vol. 18, no. 2.
20. Konstantakopoulou, E., Municchia, A.C., Luvidi, L., and Ferretti, M., Comparison of different methods for evaluating quantitative X-ray fluorescence data in copper-based artefacts, Condens. Matter, 2024. URL: https://www.mdpi.com/journal/condensedmatter.10.3390/condmat9010005 ↗
21. Syasko, V. and Polacek, A., Electromagnetic thickness measurement of coatings, situation and prospects, 11th Eur. Conf. Non-Destr. Test. (ECNDT 2014).
22. A white paper from spectro analytical instruments, nine elements that challenge handheld XRF analyzers–But are easy for OES, SPECTRO AMETEK.
23. Lane, A., Lane, A., Gokhale, A., Werner, E., Roberts, A., Freeman, A., Roberts, B., and Faundez, V., Sulfur and phosphorus-standardized metal quantification of biological specimens using inductively coupled plasma mass spectrometry, STAR Protoc., 2022. https://doi.org/10.1016/j.xpro.2022.10133410.1016/j.xpro.2022.101334 ↗
24. Takahara, H., Thickness and composition analysis of thin film samples using FP method by XRF analysis, Rigaku J., 2017, vol. 33, no. 2, pp. 17–21.
25. Chicco, D., Warrens, M.J., and Jurman, G., The coefficient of determination R-squared is more informative than SMAPE, MAE, MAPE, MSE and RMSE in regression analysis evaluation, PeerJ Comput. Sci., 2021, vol. 7, p. e623. https://doi.org/10.7717/peerj-cs.62310.7717/peerj-cs.623 ↗
26. Jalid, A., Hariri, S., and Laghzale, N.E., Influence of sample size on flatness estimation and uncertainty in three-dimensional measurement, Int. J. Metrol. Qual. Eng., 2015, vol. 6, p. 102. https://doi.org/10.1051/ijmqe/201500210.1051/ijmqe/2015002 ↗