journal article·2024-06

A Practical and Precise Technique for Determination of Beta Emitter Source in Thickness Gauging of Thin Film

S. Z. Islami rad, R. Gholipour Peyvandi

Publisher page

Abstract

Abstract The nuclear thickness gauging systems play an important role in the industry for invasive, online, and continuous measurements. The goal of the Beta thickness gauge is to obtain a precise measurement of thin films in which the performance of these gauging systems and output data quality are evaluated with the parameters including resolution, contrast, etc. The choice of the emitted suitable energy distribution of the Beta source is one of the effective factors in the system performance and precise measurement of thin films. In this research, a Beta thickness gauge with 147Pm and 85Kr sources was simulated and evaluated in biaxially oriented polypropylene sheet production lines in order to calculate the system performance due to Beta emitter sources with different energy distribution and select the suitable Beta emitter source. The relative error percentage, standard deviation, resolution, and contrast parameters for 147Pm energy distribution were calculated 1.413, 0.113, 0.007, and 0.008, respectively. Also, these parameters for 85Kr energy distribution were measured 2.750, 0.220, 0.014, and 0.001, respectively. The results reveal that the 147Pm energy distribution has superior in comparison with the 85Kr energy distribution for measuring of films or sheets with thin thickness.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Particle Detector Development and Performance · Electrostatic Discharge in Electronics · Integrated Circuits and Semiconductor Failure Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. Islami rad, S.Z., Influence of the mechanical error on performance of beta thickness gauging and the prediction of system operation time, Russ. J. Nondestr. Test., 2020, vol. 56, no. 4, pp. 369–374.10.1134/S1061830920040051 ↗
2. NDC Technologies, Beta Transmission Gauges, 2020. https://www.ndc.com/film-extrusion-and-converting/products/beta-and-gamma-gauges/beta-transmission-gauges.
3. Thermo Scientific, Beta Plus Basis Weight Sensor, 2020. https://assets.thermofisher.com/TFS-Assets/ CAD/brochures/CD-2534-TF-Betaplus.brochure-Aug23-EN.pdf.
4. Sen, M., Calik, A.E., and Ertik, H., Determination of half-value thickness of aluminum foils for different beta sources by using fractional calculus, Nucl. Instrum. Methods Phys. Res. B, 2014, vol. 335, pp. 78–84.10.1016/j.nimb.2014.06.005 ↗
5. Yalcin, S., Gurler, O., Gundogdu, O., and Bradley, D.A., A practical method for in-situ thickness determination using energy distribution of beta particles, Appl. Radiat. Isot., 2012, vol. 70, pp. 128–132.10.1016/j.apradiso.2011.08.001 ↗
6. Fuentes, F. and Gutiérrez, R.M., Thin film thickness measurement with triple gas electron multiplier detector by 55Fe radiation transmission and background detection using energy distribution analysis Instrum. Sci. Technol., 2020, vol. 48(5), pp. 1–11.10.1080/10739149.2020.1742155 ↗
7. Cengiz, A. and Almaz, E., Internal bremsstrahlung spectra of beta particle emitters using the Monte Carlo method, Radiat. Phys. Chem., 2004, vol. 70, pp. 661–668.10.1016/j.radphyschem.2004.03.008 ↗
8. Gurler, O. and Yalcin, S., A practical method for calculation of mass-attenuation coefficients of beta particles, Ann. Nucl. Energy, 2005, vol. 32, pp. 1918–1925.10.1016/j.anucene.2005.05.007 ↗
9. Kang, H., Min, S., Seo, B., Roh, Ch., Hong, S., and Cheong, J.H., Low energy beta emitter measurement: A review, Chemosensors, 2020, vol. 8, p. 106.10.3390/chemosensors8040106 ↗
10. Hou, X., Tritium and 14C in the environment and nuclear facilities: Sources and analytical methods J. Nucl. Fuel Cycle Waste Technol., 2018, vol. 16, pp. 11–39.10.7733/jnfcwt.2018.16.1.11 ↗
11. Pelowitz, D.B., MCNP-X™ User’s Manual, Version 2.5.0, IA-CP-05e0369, Los Alamos National Laboratory.
12. International Atomic Energy Agency, IAEA-TECDOC 1459, Technical Data on Nucleonic Gauges, Vienna: IAEA, 2005.
13. Knoll, G.F., Radiation Detection and Measurement, New York: Wiley, 1999, 2nd ed.
14. Tsoulfanidis, N., Measurement and Detection of Radiation, Washington: Taylor & Francis, 1995, 2nd ed.