Digital radiography of aluminum castings by fluoroscopy

W. Harara

Publisher page

Abstract

Digital fluoroscope was used as digital industrial radiography system to test three flawed Aluminum castings with dimension of (100 × 100 × 100) mm3. The digital radiographs show that, all the flaws in the three aluminum castings had been detected and their dimensions can be measured accurately. The comparison between the digital radiographs of the three aluminum castings and the digitized medium speed films radiographs of the same castings had shown that; the detection capability of flaws in the castings for the two radiography techniques were nearly identical. The sensitivity achieved by digital radiographs and by digitized films radiographs, using wire (IQI) according to EN 462-1, were W5 and W6 respectively, while the image definition achieved by digital radiographs and by digitized films, using duplex wire IQI according to EN 462-5, were 5D and 7D respectively. The results confirm that digital fluoroscopy can be applied to detect and measure flaws in relatively thick Aluminum and others light metal castings according to the requirements of the EN 444, EN 13068 and ISO 17636 class A testing.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Non-Destructive Testing Techniques · Mineral Processing and Grinding

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (10)

Show source-provided references
1. Harara, W., Digital Radiography in Industry, in 17th World Conference on Non-Destructive Testing, Shanghai, China, 2008.
2. Zscherpel, U., et al., Comparative Analysis of Radiological Detector Systems, in 8th ECNDT, Barcelona, 2002.
3. Ewert, U., et al., Strategies for Film Replacement in Radiography-Film and Digital Detectors in Comparison, in 17th World Conference on Non-Destructive Testing, Shanghai, China, 2008.
4. Meade, B., Kidwell, C., and Warren, G., Reliability and Cost Study of Digital Radiography, Film and Radioscopy, ASNT Digital Imaging Topical VI, 2003.
5. Ramesh, J., Patel, Digital Application of Radiography, in 3rd Middle East Non-Destructive Testing Conference and Exhibition, Bahrain, Manama, 2005.
6. Hammar, L. and Wirdelius, H., Radiographic Sensitivity Improved by Optimized High Resolution X-Ray Detector Design, in International Symposium on Digital Industrial Radiology and Computed Tomography, Lyon, France, 2007.
7. Zscherpel, U., et al., Possibilities and Limits of Digital Industrial Radiology. The New High Contrast Sensitivity Technique-Examples and System Theoretical Analysis, in International Symposium on Digital Industrial Radiology and Computed Tomography, Lyon, France, 2007.
8. Kononov, N.K., et al., A Digital System for Production X-Ray Images with a High Spatial Resolution, Instrum. Experim. Techniq., 2006, vol. 45, no. 5.10.1134/S002044120605023X ↗
9. Hanke, R., et al., Automated High Speed Volume Computed Tomography for Inline Quality Control, 16WCNDT, Montreal, Canada, 2004.
10. Harara, W., Low Cost Digital Radiography System for Weld Joints and Castings Testing, Russ. J. Non-Destructive Testing, 2010, vol. 46, no. 8.10.1134/S1061830910080115 ↗