journal article·2013-07

Comparison of systems for ultrasonic nondestructive testing using antenna arrays or phased antenna arrays

E. G. Bazulin

Publisher page

Abstract

This paper considers the features of forming the images of reflectors using phased antenna array technology and the images obtained by the C-SAFT method by echo signals measured in by double-scanning mode. It is shown that in some cases the images obtained by the phased antenna array technology are less informative, while the images obtained by the C-SAFT method have a higher frontal resolution over the entire area of image restoration; the partial images restored at different positions of the antenna array can be coherently combined to obtain a high and homogeneous resolution throughout the entire volume of thickwalled articles and increasing the signal/noise ratio. For the sake of brevity, the registration of echo signals in the double-scanning mode and restoration of the images of reflectors by the C-SAFT method will be called digital focusing by an antenna array (DFA). The ability to restore the partial images of reflectors by once measured echo signals according to many acoustic schemes with their consequent combination into one high-quality image should provide reliable automation of the process of recognition and dimensioning of scatterers. Another advantage of the images obtained by the C-SAFT method with three-dimensional focusing is the possibility of restoring images in the same coordinate system when using antenna arrays on prisms of different configurations. This facilitates the joint analysis of the images. Speeds of forming the images by the technology of phased-antenna arrays and the images obtained by the C-SAFT method are comparable. If the testing technique is based on the use of nonlinear effects, then in this case PA flaw detectors have a distinct advantage over DFA flaw detectors. However, within the framework of linear acoustics, PA flaw detectors have no fundamental advantages over DFA flaw detectors. It is fairer to say that PA flaw detectors have drawbacks. This article shows images that illustrate the features of the images that were obtained by PA and DFA flaw detectors.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Non-Destructive Testing Techniques · Industrial Engineering and Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Samoilenko, V.I. and Shishov, Yu.A., Upravlenie fazirovannymi antennymi reshetkami (Control of Phased Antenna Arrays), Moscow: Radio i svyaz’, 1983.
2. Osipov, L.V., Ul’trazvukovye diagnosticheskie pribory: prakt. rukovodstvo dlya pol’zovatelei (Ultrasonic Diagnostic Devices: Manual for Users), Moscow: VIDAR, 1999.
3. Gurvich, A.K., Methods of scanning in ultrasonic testing, V Mire NK, 2010, no. 3(49), pp. 4–6.
4. Advances in Phased Array Ultrasonic Technology Applications. http://www.olympus-ims.com/en/books.
5. Voronkov, V.A., Voronkov, I.V., Kozlov, V.N., Samokrutov, A.A., and Shevaldykin, V.G., On applicability of antenna arrays in ultrasonic testing of industrial entities, V Mire NK, 2011, no. 1(51), pp. 64–70.
6. Braconnier, D., Okuda, S., and Dao, G., A Detailed Study of Inspecting Thick Parts Using Large Aperture Phased Arrays and DDF, 7th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurized Components, Yokohama, 2009, p. 7.
7. Miller, E., Khill, K., Kember, Dzh., Dikinson, R., Fish, P., and Khaar, G., Primenenie ul’trazvuka v meditsine. Fizicheskie osnovy (Use of Ultrasound in Medicine. Basic Physics), Moscow: Mir, 1989.
8. Bazulin, E.G., Golubev, A.S., and Kokolev, S.A., Using ultrasonic antenna array in registration of echo signals by double-scanning for obtaining images of flaws, Russ. J. Nondestr. Test., 2009, no. 2, pp. 18–32.
9. Chatillon, S., Fidahoussen, A., Iakovleva, E., and Calmon, P., Time of flight inverse matching reconstruction of ultrasonic array data using forwards models, NDT in Canada 2009 National Confe rence, 2009.
10. Danilov, V.N., Samokrutov, A.A., and Lyutkevich, A.M., Teoreticheskie i eksperimental’nye issledovaniya maloaperturnykh pryamougol’nykh preobrazovatelei (Theoretical Experimental Studies of Low Aperture Rectangular Transducers), Moscow: Mashinostroenie. Kontrol’. Diagnostika, 2003, vol. 7, pp. 29–33.
11. Kovalev, A.V., Kozlov, V.N., Samokrutov, A.A., Shevaldykin, V.G., and Yakovlev, N.N., Pulse echo method for concrete testing. Noise and spatial selection, Russ. J. Nondestr. Test., 1990, no. 2, pp. 29–41.
12. Bulavinov, A., Dalichow, M., Kroning, M., Kurz, J.H., Walte, F., and Reddy, K., Quantitative Ultrasonic Testing of Pressurized Components Using Sampling Phased Array, Proc. National Seminar on nondestructive Evaluation, Hyderabad, 2006, pp. 7–9.
13. Bazulin, E.G., Restoring image of flaws by C-SAFT using echo signals measured by antenna matrix by triple scanning, Russ. J. Nondestr. Test., 2012, no. 1, pp. 3–19.
14. Ermolov, I.N. and Lange, Yu.V., Ultrasonic testing, in Nerazrushayushchii kontrol’. Spravochnik (Nondestructive Testing. Reference Manual), Klyuev, V.V., Ed., Moscow: Mashinostroenie, 2004, vol. 3.
15. High-frequency ultrasonic tomograph A1550 IntroVisor. http://acsys.ru/production/?type-id=16&subtype-id=7&product-id=106.
16. PA flaw detector X-32. http://www.harfang.ru/content/x-32.html.
17. PA flaw detector OMNISCAN MX. http://www.olympus-ims.com/ru/omniscan-mx/.
18. PA flaw detector MULTIX POCKET 64 × 64. http://www.m2m-ndt.com/products-1-25-en.html.
19. PA flaw detector ISONIC 2009. http://www.sonotronndt.com/i2009.htm.
20. PA flaw detector Sonatest veo. http://www.metamak.com.tr/web/metamak/VEO%20%20Brochure.pdf.
21. PA flaw detector PHASORXS. http://spektr-ksk.ru/pribor.php?id=1411.
22. PA flaw detector AGRTD. http://www.newcoinc.com/detail.aspx?ID=1478.
23. PA flaw detector CTS-602. http://www.siui.com/enH/products_view_c5_9_21_35_i28.html.
24. Ugryumov, E.P., Chapter 7. Programmable logical matrices, programmable matrix logic, base matrix crystals in Tsifrovaya skhemotekhnika. Uchebnoe posobie dlya vuzov. Izd. 2 (Digital Circuit Engineering. Textbook for High Schools. Second Edition), BKhV-Peterburg, 2004, p. 357.
25. Scanner-flaw detector A2075 SoNet, http://acsys.ru/production/?type-id=16&subtype_id=40.
26. Testing system using phased array technology FlashFocus. http://www.kjtd-indes.com/.
27. Testing system using phased array technology MutiX. http://www.m2m-ndt.com/products-1-25-en.html.
28. Testing system using phased array technology 3DFocus-UT. http://www.hitachi.com/rev/field/powersystems/__icsFiles/afieldfile/2009/04/28/r2009_02_107.pdf.
29. Schenk, G., Ploigt, R., Dohse, E., Bauer, L., and Deutsch, W.A.K., COMPAS-XXL—a novel array system with extended capabilities. http://www.ndt.net/article/ecndt2010/reports/1_03_28.pdf.
30. NVIDIACUDA™ technology. http://www.nvidia.ru/object/cuda_what_is_ru.htmlCUDA.
31. Boreskov, A. and Kharlamov, A., Osnovy raboty s tekhnologiei CUDA (Basics of Operation with the CUDA Technology), Moscow: DMK-Press, 2010.
32. Bazulin, E.G., Determination of flaw type by images obtained using C-SAFT taking into account transformation of wave types when reflecting ultrasonic pulses from rough borders of tested object, Russ. J. Nondestr. Test., 2011, no. 1, pp. 39–56.
33. Ermolov, I.N., On selection of optimal parameters of echo technique of ultrasonic flaw detection, Russ. J. Nondestr. Test., 1965, no. 6, pp. 51–61.
34. Kremer, I.Ya., Kremer, A.I., Petrov, V.M., et al., Prostranstvenno-vremennaya obrabotka signalov., (Spatiotemporal Processing of Signals), Kremer, I.Ya., Ed., Moscow: Radio i svyaz’, 1984.
35. Bazulin, E.G., Testing of sealings of Дy800 using antenna arrays by triple scanning, Russ. J. Nondestr. Test., 2010, no. 7, pp. 498–506
36. Burov, V.A. and Shmelev, A.A., Numerical and physical simulation of tomography based on acoustic nonlinear effects of the third kind, Acoust. Phys., 2009, vol. 55, no. 4–5, pp. 466–480.
37. Solodov, I.Y., Zheng, Y., and Maev, R.G., Nonlinear acoustic application for material characterization: A review, Can. J. Phys., 1999, vol. 77, no. 12, pp. 927–967.10.1139/cjp-77-12-927 ↗