journal article·1993-03

Effect of sensor configuration on magnetic Barkhausen observations

L. J. Swartzendruber, G. E. Hicho

Publisher page

Abstract

Abstract A number of characteristics of the magnetic Barkhausen signal, including power density, autocorrelation, jumpsum density, and noise emission rates, are obtained with different sensor types on low-carbon sheet steels and compared. The steel samples used in this study produced single, narrow Barkhausen peaks and the shapes of the rms voltage and jumpsum curves were found to be nearly independent of the sensor type.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Magnetic Properties and Applications · Non-Destructive Testing Techniques · Advanced Electrical Measurement Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (7)

Show source-provided references
1. R. Ranjan, D.C. Jiles, O. Buck, and R.B. Thompson.J. Appl. Phys. 613199 (1987)10.1063/1.338900 ↗
2. K. Titto.Nondestr Test Eval 527–37 (1989)10.1080/02780898908952952 ↗
3. G.L. Burkhardt and H. Kwun. InReview of Progress in Quantitative NDE 8, 2043 (1989)
4. B. Allesandro, C. Beatrice, G. Bertotti, and A. Montorsi.J. Appl. Phys. 68 2908 (1990)10.1063/1.346424 ↗
5. S. Titto.Acta Polytech. Scand. 119 1 (1977)
6. F. Fiorillo. InProceedings of the Soft Magnetic Material 7 Conference, Blackpool, 1985, p. 99. University College, Cardiff (1985)
7. L.J. Swartzendruber, L.H. Bennett, H. Ettedgui, and I. Aviram.J. Appl. Phys. 695469 (1990)10.1063/1.345848 ↗