Abstract
This article concerns magnetization methods for detecting arbitrary oriented defects by magnetic particle inspection. The authors propose a new method of magnetization with omnidirectional detection ability requiring only a single-channel DC or AC power supply. The detection of all defects by the new method can be achieved during a single testing (spraying) cycle.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Non-Destructive Testing Techniques · Surface Roughness and Optical Measurements · Minerals Flotation and Separation Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Electrical Engineering, Department of Electromagnetic Field, Czech Technical University in Prague, Praha, Czech Republic
Funding
Student Grant Competition of Czech Technical University in Prague
References (11)
Show source-provided references
1. Thomas Schmidt J. · 1989
2. ASTM · 2015
3. Hellier C. · 2003
4. IAEA Training Course Series · 2000
5. 10.1002/eej.2310910.1002/eej.23109 ↗
6. 10.31399/asm.tb.imub.978162708305810.31399/asm.tb.imub.9781627083058 ↗
7. 10.1007/s10921-019-0615-410.1007/s10921-019-0615-4 ↗
8. 10.1080/10589759.2022.206666310.1080/10589759.2022.2066663 ↗
9. 10.1063/1.486500110.1063/1.4865001 ↗
10. Mix P. E. · 2005
11. IEC · 2021