A portable device was designed and constructed for studying the properties of biomaterials in physiologically relevant fluids under controllable flow conditions that closely simulate fluid flow inside the body. The device can fit entirely inside a cell incubator; and, thus, it can be used directly under standard cell culture conditions. An impedance-driven pump was built in the sterile flow loop to control the flow rates of fluids, which made the device small and portable for easy deployment in the incubator. To demonstrate the device functions, magnesium (Mg) as a representative biodegradable material was tested in the flow device for immersion degradation under flow versus static conditions, while the flow module was placed inside a standard cell incubator. The flow rate was controlled at 0.17 ± 0.06 ml/s for this study; and, the flow rate is adjustable through the controller module outside of incubators for simulating the flow rates in the ranges of blood flow in human artery (0.05 ∼0.43 ml/s) and vein (0.02 ∼0.08 ml/s). Degradation of Mg under flow versus static conditions was characterized by measuring the changes of sample mass and thickness, and Mg2+ ion concentrations in the immersion media. Surface chemistry and morphology of Mg after immersion under flow versus static conditions were compared. The portable impedance-driven flow device is easy to fit inside an incubator and much smaller than a peristaltic pump, providing a valuable solution for studying biomaterials and implants (e.g. vascular or ureteral stents) in body fluids under flow versus static conditions with or without cells.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Tissue Engineering and Regenerative Medicine · Hydrogen Storage and Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Bioengineering, Materials Science and Engineering Program, Stem Cell Center

Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, USA

Department of Bioengineering, University of California, Riverside, Riverside, CA, USA

Department of Neurosurgery, The First Affiliated Hospital of Zhejiang University, Hangzhou, China

Funding

American Heart Association · International Collaboration Program of Zhejiang Province · Graduate Division at the University of California at Riverside · UCR

References (25)

Show source-provided references
1. Optimizing seeding and culture methods to engineer smooth muscle tissue on biodegradable polymer matrices
2. Flow-induced corrosion behavior of absorbable magnesium-based stents
3. Comparative study on corrosion behaviour of pure Mg and WE43 alloy in static, stirring and flowing Hank’s solution
4. Ex vivo blood vessel bioreactor for analysis of the biodegradation of magnesium stent models with and without vessel wall integration
5. A mechanosensory complex that mediates the endothelial cell response to fluid shear stress
6. Comparison study on four biodegradable polymer coatings for controlling magnesium degradation and human endothelial cell adhesion and spreading
7. Cytocompatibility and early inflammatory response of human endothelial cells in direct culture with Mg-Zn-Sr alloys
8. A comparison study on the degradation and cytocompatibility of Mg-4Zn-x Sr alloys in direct culture
9. Degradation of bioresorbable Mg–4Zn–1Sr intramedullary pins and associated biological responses in vitro and in vivo
10. In vitro evaluation of MgSr and MgCaSr alloys via direct culture with bone marrow derived mesenchymal stem cells
11. Parallel-plate flow chamber and continuous flow circuit to evaluate endothelial progenitor cells under laminar flow shear stress
12. Investigation on magnesium degradation under flow versus static conditions using a novel impedance-driven flow apparatus
13. A valveless micro impedance pump driven by electromagnetic actuation
14. Experimental study of the behavior of a valveless impedance pump
15. Electrochemical deposition of conductive polymers onto magnesium microwires for neural electrode applications
16. Electrochemical deposition and evaluation of electrically conductive polymer coating on biodegradable magnesium implants for neural applications
17. The effects of poly(3, 4-ethylenedioxythiophene) coating on magnesium degradation and cytocompatibility with human embryonic stem cells for potential neural applications
18. Cytocompatibility of magnesium alloys with human urothelial cells: a comparison of three culture methodologies
19. Degradation and antibacterial properties of magnesium alloys in artificial urine for potential resorbable ureteral stent applications
20. The effects of surface and biomolecules on magnesium degradation and mesenchymal stem cell adhesion
21. The effects of serum proteins on magnesium alloy degradation in vitro
22. A study on factors affecting the degradation of magnesium and a magnesium-yttrium alloy for biomedical applications
23. High‐resolution blood flow velocity measurements in the human finger
24. Direct volumetric blood flow measurement in coronary arteries by thermodilution
25. The effects of stent porosity on the endovascular treatment of intracranial aneurysms located near a bifurcation