journal article·2003-06

Novel, photon counting X-ray detectors

R. D. Durst, Y. Diawara, D. Khazins, S. Medved, B. Becker, T. Thorson

Powder Diffraction· Volume 18· Issue 2
Publisher page

Abstract

A novel sealed gaseous parallel plate avalanche chamber detector is described which is significantly less prone to discharges and can consequently achieve high gas gains at high counting rates. The detector has demonstrated stable gains greater than 10 4 at counting rates in excess of 10 7 counts/mm 2 s.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Particle Detector Development and Performance · CCD and CMOS Imaging Sensors · Medical Imaging Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (9)

Show source-provided references
1. 10.1016/S0168-9002(01)01713-210.1016/S0168-9002(01)01713-2 ↗
2. 10.1016/S0168-9002(98)00865-110.1016/S0168-9002(98)00865-1 ↗
3. 10.1016/0168-9002(88)90970-910.1016/0168-9002(88)90970-9 ↗
4. Sauli F. (1977). “Principle of operation of multiwire proportional and drift chambers,” CERN 77-09, May 1977.
5. 10.1016/0168-9002(93)90257-I10.1016/0168-9002(93)90257-I ↗
6. 10.1016/S0168-9002(96)01172-210.1016/S0168-9002(96)01172-2 ↗
7. Durst R. , Carney S. , Diawara Y. , and Shouvalov R. , “Readout structure and technique for electron cloud avalanche detectors,” US Patent: 6,340,819, 2002.
8. The CAT. Pixel proportional gas counter detector
9. 10.1016/S0168-9002(98)00962-010.1016/S0168-9002(98)00962-0 ↗