Predicting iron ore sinter strength through partial least square regression (PLSR) analysis of X-ray diffraction patterns

Nathan A.S. Webster, Mark I. Pownceby, Natalie Ware, Rachel Pattel

Powder Diffraction· Volume 32· Issue S2
Publisher page

Abstract

The decrease in quality of Australian iron ore, coupled with the demand for more efficient energy use, means that closer monitoring and optimisation of process conditions for iron ore sinter production is required. Here, the suitability of using partial least-squares regression analysis of powder X-ray diffraction data, collected for iron ore sinter samples, for the prediction of iron ore sinter strength has been further assessed. In addition, a preliminary assessment of the effect of 2 θ range on the quality of prediction has been made. For the purposes of process control, the level of correlation between predicted strength and actual sinter strength would inform an operator whether or not the process was operating within the acceptable limits, or whether there was a potential problem requiring further investigation or rapid intervention. Reducing the 2 θ range was found to reduce the level of correlation between predicted and actual strength, to a point where the particular analysis may no longer be suitable for process control.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Iron and Steelmaking Processes · Mineral Processing and Grinding · X-ray Diffraction in Crystallography

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. Webster · 2017b · 331
2. 10.2355/isijinternational.ISIJINT-2016-33210.2355/isijinternational.ISIJINT-2016-332 ↗
3. The crystal structure of SFCA-I, Ca3.18Fe3+ 14.66Al1.34Fe2+ 0.82O28, a homologue of the aenigmatite structure type, and new crystal structure refinements of β-CFF, Ca2.99Fe3+ 14.30Fe2+ 0.55O25 and Mg-free SFCA, Ca2.45Fe3+ 9.04Al1.74Fe2+ 0.16Si0.6O2010.1127/njma/173/1998/93 ↗
4. PLSR as a new XRD method for downstream processing of ores: – case study: Fe2+ determination in iron ore sinter
5. 1- and 2-dimensional detection systems and the problem of sample fluorescence in X-ray diffractometry
6. The influence of ore composition on sinter phase mineralogy and strength
7. 10.2355/isijinternational.41.12810.2355/isijinternational.41.128 ↗
8. König · 2015 · 53
9. Pownceby · 2015 · 579
10. 10.1016/S0032-5910(02)00241-310.1016/S0032-5910(02)00241-3 ↗
11. Raven M. and Birch S. (2017). ‘Development of an XRD Standard Method for Determining the Quantitative Mineralogy of Iron Ores – I. Results of an International Round Robin,’ Abstracts of the 2017 Australian X-ray Analytical Association Workshops, Conf. and Exhibition (AXAA-2017), February 5–9 2017, Melbourne, Australia, OC22.
12. Ware · 2013 · 485