journal article·2020-09

An alternative neutron diffractometer performance for strain/stress measurements

Pavol Mikula, Jan Saroun, Vasyl Ryukhtin, James Stammers

Powder Diffraction· Volume 35· Issue 3
Publisher page

Abstract

An alternative neutron diffractometer performance, which documents the feasibility of using a high-resolution three-axis neutron diffractometer for elastic and plastic deformation studies of bulk metallic polycrystalline samples, is presented. Contrary to the conventional double-axis setting, the suggested alternative consists of an unconventional three-axis set-up employing a bent perfect crystal monochromator and an analyzer with a polycrystalline sample in between. Though the alternative is, for measurements, much more time-consuming, its sensitivity to the change of the diffraction angle of the sample is, however, substantially higher and permits also plastic deformation studies on the basis of analysis of the diffraction line profiles. Moreover, much larger widths (up to 10 mm) of the irradiated gauge volumes can be investigated when just slightly affecting the angular resolution properties of the experimental setting.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Nuclear Physics and Applications · X-ray Diffraction in Crystallography · Non-Destructive Testing Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (11)

Show source-provided references
1. 10.4028/www.scientific.net/MSF.681.42610.4028/www.scientific.net/MSF.681.426 ↗
2. 10.1007/978-1-4613-9570-610.1007/978-1-4613-9570-6 ↗
3. 10.4028/www.scientific.net/MSF.228-231.26910.4028/www.scientific.net/MSF.228-231.269 ↗
4. 10.1155/TSM.33.21910.1155/TSM.33.219 ↗
5. 10.1007/BF0048272510.1007/BF00482725 ↗
6. 10.4028/www.scientific.net/MSF.571-572.18110.4028/www.scientific.net/MSF.571-572.181 ↗
7. 10.4028/www.scientific.net/MSF.404-407.59910.4028/www.scientific.net/MSF.404-407.599 ↗
8. 10.1016/0168-9002(94)90172-410.1016/0168-9002(94)90172-4 ↗
9. 10.1016/0921-5093(95)10047-410.1016/0921-5093(95)10047-4 ↗
10. 10.1007/978-94-011-2797-410.1007/978-94-011-2797-4 ↗
11. Mikula, P. , Vrána, M. , Lukáš, P. , Šaroun, J. , Strunz, P. , Ullrich, H. J. , and Wagner, V. (1997). “Neutron diffractometer exploiting Bragg diffraction optics – a high resolution strain scanner,” in Proceedings of ICRS-5, Vol. 2, edited by T. Ericsson, M. Odén and A. Andersson, June 16–18, 1997 (Linköping), pp. 721–725.