journal article·1993-03

Confirmation of the new technique for measuring the linear thermal expansion of silicon

Liu Fengchao

Powder Diffraction· Volume 8· Issue 1
Publisher page

Abstract

This paper further confirms that the direct measurement of diffraction angles at different temperatures by using the X-ray diffractometer is better than measurement of the lattice parameters for the rapid and accurate determination of the linear thermal expansion of silicon. High purity silicon has the linear expansion coefficient, α = (2.45±0.05) × 10 −6 /°C at room temperature. This value does not change for doped P -type and N -type silicon.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Silicon and Solar Cell Technologies · Semiconductor materials and interfaces · Semiconductor materials and devices

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (10)

Show source-provided references
1. 10.1107/S0365110X6000204110.1107/S0365110X60002041 ↗
2. James · 1954 · 155
3. Tao · Chinese J. Tsing Hua Univ. · 1980 · 20 · 103
4. 10.1107/S002188987500950810.1107/S0021889875009508 ↗
5. Chen Lijun (1987). “Explanation of the state standard of the People's Republic of China of No. GB8360-87” (internal report, unpublished).
6. Huang · 1988 · 284
7. Liu · Powder Diffr. · 1991 · 6 · 14710.1017/S0885715600017292 ↗
8. Shaw · Scientia Sinica · 1965 · XIV · 699
9. 10.1107/S0365110X6000197710.1107/S0365110X60001977 ↗
10. 10.1063/1.166343210.1063/1.1663432 ↗