journal article·2000-03

Heating device for high temperature X-ray powder diffraction studies under controlled water vapour pressure (0–1000 mbar) and gas temperature (20–200 ° C )

Martin Oetzel, Franz-Dieter Scherberich, Gernot Heger

Powder Diffraction· Volume 15· Issue 1
Publisher page

Abstract

In this paper we present a high temperature heating device, working under defined environmental conditions, for a Siemens D500 Bragg–Brentano powder diffractometer. The powder sample is prepared in a flat mould on a metal block consisting either of copper or of platinum depending on the temperature range selected for investigations. Although the heating cell can be used separately under ambient conditions up to sample temperatures of 1000 ° C , it is possible to work under defined environmental conditions in the temperature range between 20 and 200 ° C and up to a water vapour pressure of 1000 mbar. For that purpose a special cover for the in situ control of temperature and water vapour pressure has been constructed. It is important to note that the three sample conditions (sample temperature, gas temperature, and gas humidity) can be adjusted separately by the user. Current studies have shown that the described X-ray heating device is a powerful tool to study dehydration reactions in the frame of fundamental research as well as to understand industrially relevant processes concerning dehydration reactions and their mechanisms.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Thermal and Kinetic Analysis · X-ray Diffraction in Crystallography · Thermodynamic and Structural Properties of Metals and Alloys

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Carr-Brion, K. (1986). Moisture Sensors in Process Control (Elsevier, London), 122 pp.
2. Water of Crystallisation in the CaSO4 0.67 H2O and CaSO4 0.5 H2O Structures
3. 10.1088/0950-7671/18/5/30210.1088/0950-7671/18/5/302 ↗
4. Structures Cristallines de CaSO4, 0.5 H2O et CaSO4, 0,6 H2O
5. Identification Chimique et Radiocristallographique de Deux Formes Sous-hydratées du Sulfate de Calcium: CaSO4, 0,5 H2O et CaSO4, 0,6 H2O
6. Low- and High-Temperature Accessories for the D500 Powder Diffractometer
7. Das Verhalten von Bassanit bei Variation des äuβeren Wasserdampfpartialdrucks
8. 10.1006/jssc.1995.126010.1006/jssc.1995.1260 ↗
9. Ein einfacher Heizaufsats für Pulverdiffraktometer bis 800 °C
10. Bish, D. L. and Reynolds, R. C., Jr. (1989). Modern Powder Diffraction: Sample Preparation for X-ray Diffraction, Reviews in Mineralogy Volume 20 (Mineralogical Society of America, Washington D.C.).
11. 10.1107/S002188986900655810.1107/S0021889869006558 ↗
12. 10.1016/S0022-4596(05)80055-610.1016/S0022-4596(05)80055-6 ↗
13. 10.1107/S010827018300698810.1107/S0108270183006988 ↗
14. Beurteilung Moderner Methoden zur Quantitativen Phasenanalyse von Industriegipsen und daraus erzeugten Bindemitteln
15. 10.1016/S0040-6031(96)03119-X10.1016/S0040-6031(96)03119-X ↗
16. 10.1016/0040-6031(92)85222-H10.1016/0040-6031(92)85222-H ↗
17. 10.1016/S0040-6031(96)03120-610.1016/S0040-6031(96)03120-6 ↗
18. 10.6028/jres.081A.01110.6028/jres.081A.011 ↗
19. Brooks Instruments GmbH, Haan Office, Rheinische Strasse 2, D-42781 Haan, Germany.
20. Klug, H. P. and Alexander, L. E. (1974). X-ray Diffraction Procedures, 2nd Ed. (Wiley, New York).
21. Calcium Sulphate Hydrates: A Review
22. 10.1017/S088571560000926X10.1017/S088571560000926X ↗
23. 10.1002/ijch.19820004110.1002/ijch.198200041 ↗
24. Chemische und kristallographische Eigenschaften von Calciumsulfat–Halbhydrat und Anhydrit III
25. Oetzel, M. (unpublished).
26. Oetzel, M. (unpublished).
27. 10.1016/0921-4526(93)90108-I10.1016/0921-4526(93)90108-I ↗
28. VAISALA Oyj, P. O. Box 26, 00421 Helsinki, Finland, http://www.vaisala.com
29. Zeunert (private communication).
30. 10.1016/0021-8502(94)90378-610.1016/0021-8502(94)90378-6 ↗
31. 10.1002/ange.1995107110510.1002/ange.19951071105 ↗