article·1975-03-16

On the measurement of the thickness of epitaxial and polycrystalline silicon layers in the submicron range

P. J. Severin, F. C. Eversteyn, F. Huizinga

Publisher page

Abstract

The thickness of epitaxially grown silicon layers, less than 1 μm thick, can be measured directly with a mercury probe and an, eventually automated, capacitance bridge. The thickness measured in this way with a precision of about 400 Å, is found to be about 10% smaller than the metallurgical thickness. The submicron thickness of polycrystalline layers can be measured similarly and agrees with the metallurgical thickness within the measurement precision of about 200 Å.