article·1978-03-16

Image profiles and resolution of magnetic domains in the scanning electron microscope

J. P. Jakubovics, D. J. Fathers

Publisher page

Abstract

The resolution of magnetic domain images is estimated from image profiles calculated by computer simulation. The results are compared with those obtained by calculations based on a simple analytical theory. Contrast is found to be proportional to RU (R electron range, U0 incident beam voltage), and image profile width proportional to R for a given configuration of domain wall and incident beam. For an angle of incidence of 45°, the profile width can vary from about 0.03 to 0.2R according to the domain wall orientation and plane of incidence. The contrast of periodic domain structures is calculated as a function of Q and U0 (Q domain size). The contrast is independent of Q when Q > 1/3 R, but decreases with decreasing Q when Q < 1/3 R. The contrast is a maximum at a value of U0 which increases with Q. The resolution depends on the minimum contrast that can be detected.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Advanced Electron Microscopy Techniques and Applications · Advancements in Photolithography Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References