article·1975-12-16

On the of Choice γ-Ray Sources for Compton Profile Studies

P. Chaddah, V. C. Sahni

Publisher page

Abstract

A careful study is made of the different factors governing the choice of a γ-ray source, and other experimental parameters (scattering angle, collimation) when performing a Compton scattering experiment using a solid state detector. As is known, the poorer penetration of lower energy γ-rays leads to a lower count rate. It is found that an optimum choice of scattering angle and collimation can, in many cases, substantially offset this effect. A detailed comparison of the two sources most commonly used, viz. 241Am and 123mTe, is made. It is shown in contrast to what has been previously reported in literature, that 241Am can be quite a worthwhile choice. Some errors in previous findings are also pointed out.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Crystallography and Radiation Phenomena · Medical Imaging Techniques and Applications · Nuclear Physics and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References