article·1977-10-16

Characterization of ion implanted silicon by the electrolytic reverse current

J. Hüller, M.T. Pham

Publisher page

Abstract

The current–voltage behaviour of ion implanted silicon electrodes in HF electrolyte is investigated. The electrolytic reverse current, i.e. the reaction rate of the minority carrier limited reactions is found to increase. The current increase depends on the implanted dose and layer stripping. Reason for the increased reverse current can be referred to radiation damage acting as generation centres for minority carriers. Measurement of the electrolytic reverse current can be used for determination of damage profiles. Layer stripping is carried out by anodic dissolution in the same electrolyte. The sensitivity of this new method for characterizing ion implanted silicon layers lies at 1011 to 1012 atoms cm−2.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Silicon Nanostructures and Photoluminescence · Semiconductor materials and devices · Silicon and Solar Cell Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.