article·1985-09-16

On the Analysis of Complex Thermally Stimulated Capacitance Curves

Massimo Di Giulio, G. Micocci, Pietro Siciliano, A. Tepore

Publisher page

Abstract

A simple analytical method is suggested for analysing a thermally stimulated capacitance (TSCAP) curve where the steps are not well resolved due to the interference from the neighbouring steps. By means of this method, it is possible to decompose analytically such a complex TSCAP curve into a set of separate peaks of d(ΔC)2/dT versus temperature and to calculate the activation energies and capture cross-sections of traps with a better accuracy. The method is tested to analyse the TSCAP measurements of AuInSe Schottky diodes.