article·1971-03-16

The measurements of temperature dependence of thermal conductivity of silver for different fixed values of heat flux density (liquid helium temperature range)

J. Rafałowicz, K. Balcerek, B. Sujak, E. Pega

Publisher page

Abstract

Measurements are made of the temperature dependence of the thermal conductivity coefficient for seven fixed values of heat flux density (q) flowing along a silver sample of technical purity in the helium temperature range. The temperature dependence of the thermal conductivity coefficient is determined using a difference method, Kr(ΔT), and a graphical differential method, Krg(T). The existence of a family of curves with q as a parameter is established in the temperature region of pronounced temperature dependence of the thermal conductivity. It is concluded that the thermal conductivity coefficient for silver investigated is also a function of the heat flow density in the temperature range of the pronounced temperature dependence of the thermal conductivity. In the range of the low temperature branch of K(T) the analytical dependence of the thermal conductivity coefficient on the density of heat flux, is found to be in agreement with theoretical considerations.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Heat Transfer and Boiling Studies · Geothermal Energy Systems and Applications · Spacecraft and Cryogenic Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.