Improvement in the signal-to-noise ratio in far infrared spectroscopy due to the use of a gallium-doped germanium bolometer
Source abstract
Abstract
Using a very well defined material, a description is given of the electronic and optical schemes. A comparison of a Golay detector mounted at the focus of an ellipsoidal mirror with the germanium bolometer at the end of a cylindrical light pipe, corner mirror, and filters whose gross transmission is only 2%, shows that the germanium bolometer is still favoured by a factor greater than 18. Hence NEP(Ge + optics) ≈ 5 × 10−12 and NEP(Ge) ≈ ≈ 10−13 W Hz−1/2. The second value is the best one described up today. It could be still improved by a factor two.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Photonic and Optical Devices · Spectroscopy and Laser Applications · Optical and Acousto-Optic Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.