Thermal Effects on Depth Distribution of Mtrogen Atoms Implanted in Ferrous Alloys
Source abstract
Abstract
The influence of temperature during implantation or annealing on the total amount of retained nitrogen and its depth distribution are investigated. After implantations at temperatures above 250 °C only traces of nitrogen are detected in single crystal iron and about 30% is retained in the steel samples. The in-bulk diffusion is observed for steel above 300 °C.