Assessment of Fire Performance of Typical Furniture Foams with and without Fire Retardants Using a Cone Calorimeter

W.K. Chow, S.S. Han, W.R. Zeng

Cellular Polymers· Volume 29· Issue 2
Publisher page

Abstract

Both thermal and smoke aspects on typical samples of furniture foams with and without fire retardants available in the market were tested with a cone calorimeter. To study their behaviour under big fires, high incident radiative heat fluxes up to 70 kWm -2 were adjusted. Transient curves on heat release rate, mass loss rate, carbon monoxide concentration, carbon dioxide concentration, smoke release rate and other key parameters were measured. Further, chemical constituents of the fire retardants were analyzed by X-ray fluorescence, Fourier Transform Infrared, Gas Chromatography/Mass Spectrometry and Pyrolysis Gas Chromatography Mass Spectrometry. It is observed that foam treated with fire retardant would not be ignited under an incident heat flux of 10 kWm -2 . However, when burning under heat fluxes higher than 20 kWm -2 , there is not much improvement in the thermal aspect for foam treated with fire retardants. Even more smoke and toxic gases such as carbon monoxide was emitted. Therefore, testing ignitibility of furniture foam materials under a small match flame is not adequate. Tests with high radiative heat flux encountered in big fires are suggested. Cone calorimeter tests proposed in this paper would give a better assessment on fire safety. Finally, three risk parameters are proposed to work out a combustibility database.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Flame retardant materials and properties · Combustion and Detonation Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Research Centre for Fire Engineering, Department of Building Services Engineering, Area of Strength: Fire Safety Engineering, The Hong Kong Polytechnic University, Hong Kong, China

State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, China

References (25)

Show source-provided references
1. Chow W.K. · Invited Lecture · 2008
2. South China Morning Post, Mei Foo Sun Chuen fire, 17 April, 1997.
3. Fire Services Department · FSD Circular Letter 1/2000 · 2000
4. Sundström B. · 1995
5. 10.1002/fam.81005030510.1002/fam.810050305 ↗
6. Gigi Lui C.H. · Paper presented at the 6th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings · 2007
7. 10.3801/IAFSS.FSS.8-141310.3801/IAFSS.FSS.8-1413 ↗
8. 10.1177/073490410808956710.1177/0734904108089567 ↗
9. 10.1106/1Q30-NLP1-V354-4LY210.1106/1Q30-NLP1-V354-4LY2 ↗
10. International Standards Organization · ISO 5660–1: 1993 · 1993
11. Babrauskas V. · 1992
12. 10.1177/07349041940120010210.1177/073490419401200102 ↗
13. 10.1002/(SICI)1099-1018(199703)21:2<53::AID-FAM593>3.0.CO;2-810.1002/(SICI)1099-1018(199703)21:2<53::AID-FAM593>3.0.CO;2-8 ↗
14. 10.1177/07349040276257475810.1177/073490402762574758 ↗
15. 10.1177/07349041840020010310.1177/073490418400200103 ↗
16. Babrauskas V. · 1991
17. 10.1002/jbm.a.3006710.1002/jbm.a.30067 ↗
18. Ou Y.X. · 1991
19. 10.1177/07349041930110010310.1177/073490419301100103 ↗
20. Boulet J.C. · Halogenated polyether polyols and polyurethane foams produced therefrom · 1979
21. Chow C.L. · Proceedings of the International Symposium on Fire Science and Fire-protection Engineering (2003 ISFSFE) · 2003
22. 10.1016/j.polymertesting.2005.06.00910.1016/j.polymertesting.2005.06.009 ↗
23. 10.2190/1XTM-EBXL-6837-2FJM10.2190/1XTM-EBXL-6837-2FJM ↗
24. 10.1002/fam.81016010310.1002/fam.810160103 ↗
25. 10.1002/fam.81018040310.1002/fam.810180403 ↗