Electrochemical and Nanostructural Characterization of Poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) Films as Coatings for Neural Electrodes
Source abstract
Abstract
High Resolution Image Download MS PowerPoint Slide Poly(3,4-ethylenedioxythiophene) (PEDOT), a well-characterized conducting polymer, has been applied for coating metal neural electrodes to improve their stimulating or recording performance. The coated electrodes possess advantages in better neuron attachment, lower impedance, and larger capacitance compared to the bare metal substrate due to the biocompatibility and porous surface of the polymer. However, the PEDOT-coated electrodes have frequently reported issues associated with mechanical instability, such as cracking and delamination. Solving this problem is crucial for stimulating electrodes, whereas a massive film is unnecessary for recording purposes. Moreover, the thickness control for the latter has rarely been investigated. In this work, we systematically studied and characterized poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) with cyclic voltammetry and atomic force microscopy (AFM) to evaluate the electropolymerization of PEDOT:PSS from the basis and analyze the surface morphology for a range of deposition times. The polymerization potential was obtained, and the deposition charge density was optimized for recording neural electrodes. In addition, high-resolution AFM height and phase images reveal the heterogeneity of the polymer surface. The modified electrode was also tested for its electrochemical performance in a small potential window with both a standard electrochemical cell setup and stainless steel microscrews. The results showed that despite a shift of potential (0.42 V) due to the change of setup, the electrode functions well in the capacitive region without triggering redox reactions.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Conducting polymers and applications · Neuroscience and Neural Engineering · Advanced Sensor and Energy Harvesting Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Clarendon Laboratory, Department of Physics, University of Oxford, Parks Road, Oxford OX1 3PU, Great Britain
Physical and Theoretical Chemistry Laboratory, Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3PU, Great Britain
References (39)
Show source-provided references
1. 10.1016/j.tibtech.2016.06.00710.1016/j.tibtech.2016.06.007 ↗
2. 10.1016/j.actbio.2015.12.02210.1016/j.actbio.2015.12.022 ↗
3. 10.1039/C0PY00077A10.1039/C0PY00077A ↗
4. 10.1016/0022-0728(95)04156-810.1016/0022-0728(95)04156-8 ↗
5. 10.1109/tnsre.2007.90981110.1109/tnsre.2007.909811 ↗
6. 10.1016/j.actbio.2014.04.00410.1016/j.actbio.2014.04.004 ↗
7. 10.1021/la800333g10.1021/la800333g ↗
8. 10.1002/admi.20200067510.1002/admi.202000675 ↗
9. 10.1016/S0925-4005(02)00448-310.1016/S0925-4005(02)00448-3 ↗
10. 10.1088/1741-2560/3/1/00710.1088/1741-2560/3/1/007 ↗
11. 10.1002/jbm.a.3494510.1002/jbm.a.34945 ↗
12. 10.1021/acsami.9b0308810.1021/acsami.9b03088 ↗
13. 10.1002/adfm.20170032910.1002/adfm.201700329 ↗
14. 10.1016/j.synthmet.2008.10.01410.1016/j.synthmet.2008.10.014 ↗
15. 10.1016/S0013-4686(03)00143-910.1016/S0013-4686(03)00143-9 ↗
16. 10.1134/S102319351813021910.1134/S1023193518130219 ↗
17. 10.1016/j.electacta.2021.13947210.1016/j.electacta.2021.139472 ↗
18. 10.1021/cm402200310.1021/cm4022003 ↗
19. 10.1126/sciadv.140025110.1126/sciadv.1400251 ↗
20. 10.1016/j.synthmet.2013.12.01310.1016/j.synthmet.2013.12.013 ↗
21. 10.1039/d1tc00625h10.1039/d1tc00625h ↗
22. 10.1016/j.biomaterials.2012.05.01710.1016/j.biomaterials.2012.05.017 ↗
23. 10.1002/app.5180410.1002/app.51804 ↗
24. 10.1038/s41583-019-0169-610.1038/s41583-019-0169-6 ↗
25. 10.1038/s41596-020-0389-210.1038/s41596-020-0389-2 ↗
26. 10.1016/S0022-0728(00)00206-010.1016/S0022-0728(00)00206-0 ↗
27. 10.1002/adhm.20190076510.1002/adhm.201900765 ↗
28. 10.1016/j.actbio.2004.09.00610.1016/j.actbio.2004.09.006 ↗
29. 10.1016/j.biomaterials.2011.04.05110.1016/j.biomaterials.2011.04.051 ↗
30. 10.3390/bios504061810.3390/bios5040618 ↗
31. 10.1063/1.496286610.1063/1.4962866 ↗
32. 10.1038/nnano.2010.6710.1038/nnano.2010.67 ↗
33. Igor Pro Manual Version 9. 2017, https://www.wavemetrics.net/doc/IgorMan.pdf (accessed May 25, 2023).
34. 10.1039/B9NR00248K10.1039/B9NR00248K ↗
35. 10.1016/S0039-6028(03)00388-110.1016/S0039-6028(03)00388-1 ↗
36. 10.1021/acs.macromol.0c0087710.1021/acs.macromol.0c00877 ↗
37. Xia, Z.; Arias-Gil, G.; Deckert, M.; Vollmer, M.; Curran, A.; Herrera-Molina, R.; Brosch, M.; Krug, K.; Schmidt, B.; Ohl, F. W.; Lippert, M. T.; Takagaki, K. Electrochemical Roughening and Carbon Nanotube Coating of Tetrodes for Chronic Single-Unit Recording. bioRxiv. 2019, 738245, 10.1101/738245.10.1101/738245 ↗
38. 10.3389/fncom.2013.0013710.3389/fncom.2013.00137 ↗
39. 10.1016/j.neuron.2016.10.02010.1016/j.neuron.2016.10.020 ↗