Abstract

Low density cellular polymers have established a significant share of the market for insulating materials in the building industry due to their unique combination of low density and low thermal conductivity. Manufacturers of rigid foam insulation boards have had to satisfy fire performance criteria required by national standards and by insurance organisations. Since cellular polymers are usually installed behind inorganic or metallic facings, small-scale fire tests are only relevant for development and quality control purposes. The characteristics of the fire behaviour of different rigid foams (i.e. PS, PUR, PIR and PF) are discussed. Assessment of the potential fire hazard of an insulation board in use requires large-scale testing facilities. Evaluations of roofboard in the Factory Mutual Calorimeter and lining board in Corner Tests, including the FOC Wall and Ceiling Lining Test, are described. By careful material selection and composite engineering, the fire hazard of rigid foam insulation boards in building applications has been significantly reduced.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Analysis of Composite Materials · Flame retardant materials and properties · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

ICI Corporate Fire Laboratory, Imperial Chemical Industries PLC, Organics Division, PO Box 42, Hexagon House, Blackley, Manchester M9 3DA, UK

References (12)

Show source-provided references
1. Deutsches Institut für Normung, German Standard DIN 4102, 1981, Part 1, B1.
2. French Standard NF P92-501, 1975.
3. Paul K. T. · 1976
4. Ball G. W. · Plastics and Polymers · 1972 · 40 · 290
5. European Patent 0019998 A1, 1CI, published 10 December, 1980.
6. Modern Plastics International, October 1981, 48–50.
7. British Standards Institution, BS 5946, 1980.
8. Factory Mutual Research Corporation, USA, Approval Standard 4450, 1977.
9. 10.1177/0021955X760120040310.1177/0021955X7601200403 ↗
10. Final report of the X30-18 Round Robin, ASTM D20.30.03 Task Group, 1979.
11. ASTM D3894-81.
12. Ellis W. J. · Fire Prevention · 1982 · 154 · 21