journal article·2022-09Open access

Fault diagnosis of PEMFC based on the AC voltage response and 1D convolutional neural network

Shangwei Zhou, Tom Tranter, Tobias P. Neville, Paul R. Shearing, Dan J.L. Brett, Rhodri Jervis

Cell Reports Physical Science· Volume 3· Issue 9

Abstract

Real-time diagnosis is required to ensure the safety, reliability, and durability of the polymer electrolyte membrane fuel cell (PEMFC) system. Two categories of methods are (1) intrusive, time consuming, or require alterations to the cell architecture but provide detailed information about the system or (2) rapid and benign but low-information-yielding. A strategy based on alternating current (AC) voltage response and one-dimensional (1D) convolutional neural network (CNN) is proposed as a methodology for detailed and rapid fuel cell diagnosis. AC voltage response signals contain within them the convoluted information that is also available via electrochemical impedance spectroscopy (EIS), such as capacitive, inductive, and diffusion processes, and direct use of time-domain signals can avoid time-frequency conversion. It also overcomes the disadvantage that EIS can only be measured under steady-state conditions. The utilization of multi-frequency excitation can make the proposed approach an ideal real-time diagnostic/characterization tool for fuel cells and other electrochemical power systems.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fuel Cells and Related Materials · Analytical Chemistry and Sensors · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (45)

Show source-provided references
1. Mechanical failure and mitigation strategies for the membrane in a proton exchange membrane fuel cell10.1016/j.rser.2019.109289 ↗
2. Dead-ended anode polymer electrolyte fuel cell stack operation investigated using electrochemical impedance spectroscopy, off-gas analysis and thermal imaging10.1016/j.jpowsour.2013.11.125 ↗
3. Characterization of water management in metal foam flow-field based polymer electrolyte fuel cells using in-operando neutron radiography10.1016/j.ijhydene.2019.11.069 ↗
4. A novel fuel cell design for operando energy-dispersive x-ray absorption measurements10.1088/1361-648X/ac0476 ↗
5. A review of fault tolerant control strategies applied to proton exchange membrane fuel cell systems10.1016/j.jpowsour.2017.05.058 ↗
6. Machine learning as an online diagnostic tool for proton exchange membrane fuel cells10.1016/j.coelec.2021.100867 ↗
7. Diagnosis of PEM fuel cell drying and flooding based on power converter ripple10.1109/TIM.2014.2318371 ↗
8. Analysis of accelerated degradation of a HT-PEM fuel cell caused by cell reversal in fuel starvation condition10.1016/j.ijhydene.2014.12.082 ↗
9. A non-intrusive signal-based method for a proton exchange membrane fuel cell fault diagnosis10.1002/fuce.201600070 ↗
10. Data-driven fault diagnosis for PEMFC systems of hybrid tram based on deep learning10.1016/j.ijhydene.2020.03.035 ↗
11. Hydrogen fuel cell diagnostics using random forest and enhanced feature selection10.1016/j.ijhydene.2019.10.127 ↗
12. Signal-based diagnostic approach to enhance fuel cell durability10.1016/j.jpowsour.2021.230223 ↗
13. Fuel cell diagnosis method based on multifractal analysis of stack voltage signal10.1016/j.ijhydene.2013.11.066 ↗
14. Signal-based diagnostics by wavelet transform for proton exchange membrane fuel cell10.1016/j.egypro.2015.07.708 ↗
15. Evaluation of an on-site cell voltage monitor for fuel cell systems10.1016/j.ijhydene.2008.07.017 ↗
16. Online implementation of SVM based fault diagnosis strategy for PEMFC systems10.1016/j.apenergy.2015.11.060 ↗
17. Fault diagnosis for fuel cell systems: A data-driven approach using high-precise voltage sensors10.1016/j.renene.2018.09.077 ↗
18. Data-driven diagnosis of PEM fuel cell: a comparative study10.1016/j.conengprac.2014.02.019 ↗
19. Brain-inspired computational paradigm dedicated to fault diagnosis of PEM fuel cell stack10.1016/j.ijhydene.2016.11.043 ↗
20. Polymer electrolyte membrane fuel cell fault diagnosis based on empirical mode decomposition10.1016/j.jpowsour.2015.09.041 ↗
21. A novel method for polymer electrolyte membrane fuel cell fault diagnosis using 2D data10.1016/j.jpowsour.2020.228894 ↗
22. Data-based flooding fault diagnosis of proton exchange membrane fuel cell systems using LSTM networks10.1016/j.egyai.2021.100056 ↗
23. AC impedance technique in PEM fuel cell diagnosis—a review10.1016/j.ijhydene.2007.05.036 ↗
24. Change of electrochemical impedance spectra (EIS) with time during CO-poisoning of the Pt-anode in a membrane fuel cell10.1016/j.jpowsour.2003.09.031 ↗
25. Characterisation of proton exchange membrane fuel cell (PEMFC) failures via electrochemical impedance spectroscopy10.1016/j.jpowsour.2006.03.067 ↗
26. Diagnostic tools in PEM fuel cell research: Part I Electrochemical techniques10.1016/j.ijhydene.2008.01.013 ↗
27. Study of PEM fuel cell performance by electrochemical impedance spectroscopy10.1016/j.ijhydene.2010.03.069 ↗
28. Impedance analysis of the effect of flooding in the cathode catalyst layer of the polymer electrolyte fuel cell10.1016/j.electacta.2013.06.055 ↗
29. Study of low concentration CO poisoning of Pt anode in a proton exchange membrane fuel cell using spatial electrochemical impedance spectroscopy10.1016/j.jpowsour.2014.06.146 ↗
30. Localised electrochemical impedance measurements of a polymer electrolyte fuel cell using a reference electrode array to give cathode-specific measurements and examine membrane hydration dynamics10.1016/j.jpowsour.2018.02.022 ↗
31. Detection of membrane drying, fuel cell flooding, and anode catalyst poisoning on PEMFC stacks by electrochemical impedance spectroscopy10.1149/1.2179200 ↗
32. Detecting proton exchange membrane fuel cell hydrogen leak using electrochemical impedance spectroscopy method10.1016/j.jpowsour.2013.07.018 ↗
33. A double-fuzzy diagnostic methodology dedicated to online fault diagnosis of proton exchange membrane fuel cell stacks10.1016/j.jpowsour.2014.07.157 ↗
34. Fault detection and isolation of high temperature proton exchange membrane fuel cell stack under the influence of degradation10.1016/j.jpowsour.2017.05.021 ↗
35. Nature-inspired flow-fields and water management for PEM fuel cells10.1149/09809.0145ecst ↗
36. 1D convolutional neural networks and applications: a survey10.1016/j.ymssp.2020.107398 ↗
37. Attention is all you need
38. End-to-end environmental sound classification using a 1D convolutional neural network10.1016/j.eswa.2019.06.040 ↗
39. Gradient-based learning applied to document recognition10.1109/5.726791 ↗
40. Imagenet classification with deep convolutional neural networks
41. Bearing fault diagnosis based on vibro-acoustic data fusion and 1D-CNN network10.1016/j.measurement.2020.108518 ↗
42. Pytorch: an imperative style, high-performance deep learning library
43. An evaluation method for feature selection in proton exchange membrane fuel cell fault diagnosis
44. Identifying degradation patterns of lithium ion batteries from impedance spectroscopy using machine learning
45. State-of-health identification of lithium-ion batteries based on nonlinear frequency response analysis: first steps with machine learning10.3390/app8050821 ↗