Integrated wearable smart sensor system for real-time multi-parameter respiration health monitoring
Source abstract
Abstract
Monitoring respiration is vital for personal diagnosis of chronic diseases. However, the existing respiratory sensors have severe limitations, such as single function, finite detection parameters, and lack of smart signal analysis. Here, we present an integrated wearable and low-cost smart respiratory monitoring sensor (RMS) system with artificial intelligence (AI)-assisted diagnosis of respiratory abnormality by detecting multi-parameters of human respiration. Coupling with intelligent analysis and data mining algorithms embedded in a phone app, the lighter system of 7.3 g can acquire real-time self-calibrated parameters, including breathing frequency, apnea hypopnea index (AHI), vital capacity (VC), peak expiratory flow (PEF), and other respiratory indexes with an accuracy >95.21%. The data can be wirelessly transferred to the user’s data cloud terminal. The RMS system enables comprehensive multi-physiological parameters analysis for auxiliary diagnosing and classifying diseases, including sleep apnea, rhinitis, and chronic lung diseases, as well as rehabilitation of COVID-19, and exhibits advantages of portable healthcare.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Obstructive Sleep Apnea Research · Non-Invasive Vital Sign Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. Triboelectric nanogenerator using microdome-patterned PDMS as a wearable respiratory energy harvester10.1002/admt.201700014 ↗
2. An integrated flexible self-powered wearable respiration sensor10.1016/j.nanoen.2019.06.025 ↗
3. Active-sensing epidermal stretchable bioelectronic patch for Noninvasive,Conformal,and wireless tendon monitoring
4. All-nanofiber self-powered skin-interfaced real-time respiratory monitoring system for obstructive sleep apnea-hypopnea syndrome diagnosing10.1002/adfm.202103559 ↗
5. Constructing highly tribopositive elastic yarn through interfacial design and assembly for efficient energy harvesting and human-interactive sensing10.1016/j.nanoen.2022.106956 ↗
6. A wearable pyroelectric nanogenerator and self-powered breathing sensor10.1016/j.nanoen.2017.05.056 ↗
7. Ag nanoparticle-based triboelectric nanogenerator to scavenge wind energy for a self-charging power unit10.1021/acsami.7b14618 ↗
8. Polyimide/graphene nanocomposite foam-based wind-driven triboelectric nanogenerator for self-powered pressure sensor10.1002/admt.201800723 ↗
9. A portable triboelectric nanogenerator for real-time respiration monitoring10.1186/s11671-019-3187-4 ↗
10. A flexible capacitive pressure sensor for wearable respiration monitoring system
11. Stretching-enhanced triboelectric nanogenerator for efficient wind energy scavenging and ultrasensitive strain sensing10.1016/j.nanoen.2020.104920 ↗
12. A triboelectric nanogenerator exploiting the Bernoulli effect for scavenging wind energy
13. Wind-driven triboelectric nanogenerators for scavenging biomechanical energy10.1021/acsaem.8b00902 ↗
14. Artificial intelligence of things (AIoT) enabled virtual shop applications using self-powered sensor enhanced soft robotic manipulator10.1002/advs.202100230 ↗
15. AI enabled sign language recognition and VR space bidirectional communication using triboelectric smart glove10.1038/s41467-021-25637-w ↗
16. Silk fibroin based transparent and wearable humidity sensor for ultra-sensitive respiration monitoring10.1016/j.matlet.2019.126945 ↗
17. Air-flow-driven triboelectric nanogenerators for self-powered real-time respiratory monitoring10.1021/acsnano.8b02562 ↗
18. A facile respiration-driven triboelectric nanogenerator for multifunctional respiratory monitoring10.1016/j.nanoen.2019.01.042 ↗
19. Robust triboelectric information-mat enhanced by multi-modality deep learning for smart home
20. Artificial intelligence of toilet (AI-Toilet) for an integrated health monitoring system (IHMS) using smart triboelectric pressure sensors and image sensor10.1016/j.nanoen.2021.106517 ↗
21. Flexible triboelectric generator10.1016/j.nanoen.2012.01.004 ↗
22. Toward large-scale energy harvesting by a nanoparticle-enhanced triboelectric nanogenerator10.1021/nl4001053 ↗
23. Human exhaled air energy harvesting with specific reference to PVDF film
24. In situ quantitative study of nanoscale triboelectrification and patterning10.1021/nl401006x ↗
25. Quantifying and understanding the triboelectric series of inorganic non-metallic materials10.1038/s41467-020-15926-1 ↗
26. Alternating Current Photovoltaic Effect10.1002/adma.202001532 ↗
27. Theoretical investigation and experimental verification of the self-powered acceleration sensor based on triboelectric nanogenerators (TENGs)10.1016/j.eml.2020.101021 ↗
28. A self-powered and high sensitivity acceleration sensor with V-Q-a model based on triboelectric nanogenerators (TENGs)10.1016/j.nanoen.2019.104228 ↗
29. Wind energy harvesting based on fluttering double-flag type triboelectric nanogenerators10.1016/j.nanoen.2020.104526 ↗
30. Frequency and voltage response of a wind-driven fluttering triboelectric nanogenerator10.1038/s41598-019-42128-7 ↗
31. A novel humidity resisting and wind direction adapting flag-type triboelectric nanogenerator for wind energy harvesting and speed sensing10.1016/j.nanoen.2020.105279 ↗
32. A wind vector detecting system based on triboelectric and photoelectric sensors for simultaneously monitoring wind speed and direction10.1016/j.nanoen.2021.106382 ↗
33. Fuzzy inference system for sensor array calibration: prediction of CO and CH 4 levels in variable humidity conditions10.1016/S0169-7439(02)00069-2 ↗
34. Humidity-activated ammonia sensor with excellent selectivity for exhaled breath analysis10.1016/j.snb.2021.129625 ↗
35. Gaps in COPD guidelines of low- and middle-income countries: a systematic scoping review10.1016/j.chest.2020.09.260 ↗
36. COVID-19 recovery: potential treatments for post-intensive care syndrome10.1016/S2213-2600(20)30457-4 ↗
37. Relative strength of relationships of nasal congestion and ocular symptoms with sleep, mood and productivity10.1185/03007990903021968 ↗
38. Rhinitis and sleep10.1016/j.smrv.2010.12.001 ↗
39. Sleep disorders10.1016/j.mpmed.2018.09.008 ↗
40. Assessing severity of obstructive sleep apnea by fractal dimension sequence analysis of sleep EEG10.1016/j.physa.2009.07.005 ↗
41. Factors associated with death and ICU referral among COVID-19 patients hospitalized in the secondary referral academic hospital in East Jakarta, Indonesia
42. CALL score and RAS score as predictive models for coronavirus disease 2019
43. Pathophysiology of COVID-19-associated acute respiratory distress syndrome: a multicentre prospective observational study10.1016/S2213-2600(20)30370-2 ↗
44. Spontaneous pneumomediastinum: a collaborative sequelae between COVID-19 and self-inflicted lung injury - a case report and literature review10.1016/j.radcr.2021.08.076 ↗
45. Low cost exoskeleton manipulator using bidirectional triboelectric sensors enhanced multiple degree of freedom sensory system10.1038/s41467-021-23020-3 ↗
46. Asymptomatic infection and transmission of COVID-19 among clusters: systematic Review and Meta-Analysis