journal article·2025-10-17

Accurate Nondestructive Determination of Interfacial Oxide Layer Thickness on Si Wafers Using THz Inductive-Capacitive Resonant Metamaterial Spectroscopy

Heena Khand, Rudrarup Sengupta, Gabby Sarusi

ACS Applied Nano Materials· Volume 8· Issue 41
Publisher page

Abstract

We present a nondestructive technique to accurately measure interfacial oxide layer thickness using inductive-capacitive (LC) resonant metamaterial terahertz (THz) impedance spectroscopy. THz LC resonant metamaterials demonstrate high sensitivity to changes of the substrate’s effective relative permittivity/refractive index. This sensitivity is manifested by a change in the metamaterial’s natural resonating frequency. Utilizing this property, we built an analytical model and experimental tool to determine the interfacial oxide layer thickness. It is supported by 3D electromagnetic simulations and terahertz spectroscopic results, utilizing our highly sensitive arrowhead LC resonant metamaterial sensor. This method can detect changes in interfacial oxide layer thickness with an accuracy of 2 nm and sensitivity of 1200 GHz/RIU, which is one of the highest sensitivities to date for determining the interfacial dielectrics. We also demonstrate a complete correlation of the simulations with spectroscopic experiments, verified by measuring the real oxide thickness using a focused-ion beam. This nondestructive method enables accurate profiling of the interfacial oxide across the wafer.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Terahertz technology and applications · Semiconductor materials and interfaces · Silicon Nanostructures and Photoluminescence

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Photonics and Electro-Optics Engineering, School of Electrical and Computer Engineering

Ben-Gurion University of the Negev

Funding

Ben-Gurion University of the Negev

References (32)

Show source-provided references
1. 10.1016/0040-6090(76)90276-510.1016/0040-6090(76)90276-5 ↗
2. 10.1016/0030-4018(91)90567-W10.1016/0030-4018(91)90567-W ↗
3. 10.1063/1.162249010.1063/1.1622490 ↗
4. 10.1116/1.170186410.1116/1.1701864 ↗
5. 10.12693/APhysPolA.116.S-9210.12693/APhysPolA.116.S-92 ↗
6. 10.1134/S106377100806006710.1134/S1063771008060067 ↗
7. 10.1016/j.ndteint.2015.08.00410.1016/j.ndteint.2015.08.004 ↗
8. 10.1063/1.513035110.1063/1.5130351 ↗
9. 10.1109/LMWC.2013.224905610.1109/LMWC.2013.2249056 ↗
10. 10.1515/nanoph-2021-052010.1515/nanoph-2021-0520 ↗
11. 10.1007/s11082-022-04340-010.1007/s11082-022-04340-0 ↗
12. 10.3390/ma1209151910.3390/ma12091519 ↗
13. 10.34133/2020/254760910.34133/2020/2547609 ↗
14. 10.1021/acsanm.2c0095410.1021/acsanm.2c00954 ↗
15. 10.1016/j.sbsr.2024.10063910.1016/j.sbsr.2024.100639 ↗
16. 10.1515/nanoph-2017-009310.1515/nanoph-2017-0093 ↗
17. Gabby, S.; Rudrarup, S. Prompt Viruses Infection Detection Using THz Spectroscopy in a Breathalyzer-Like Configuration. US patent number US20230221248A1, 2023.
18. 10.1117/12.302777310.1117/12.3027773 ↗
19. 10.1038/srep0498810.1038/srep04988 ↗
20. 10.1364/OE.22.03046710.1364/OE.22.030467 ↗
21. 10.1002/advs.20240782410.1002/advs.202407824 ↗
22. 10.1038/nature0977610.1038/nature09776 ↗
23. 10.1364/BOE.8.00355110.1364/BOE.8.003551 ↗
24. 10.3390/s2011313310.3390/s20113133 ↗
25. 10.1016/j.cap.2014.01.01510.1016/j.cap.2014.01.015 ↗
26. 10.1002/lpor.20230016510.1002/lpor.202300165 ↗
27. 10.1021/acsami.4c0618710.1021/acsami.4c06187 ↗
28. 10.1117/12.302777810.1117/12.3027778 ↗
29. 10.1002/lpor.20250002310.1002/lpor.202500023 ↗
30. 10.1002/advs.20250433110.1002/advs.202504331 ↗
31. 10.1364/OE.18.00108510.1364/OE.18.001085 ↗
32. 10.1016/j.physleta.2021.12752310.1016/j.physleta.2021.127523 ↗