Inkjet printed flexible electrodes for surface electromyography
Source abstract
Abstract
Abstract Recording of surface ElctroMyoGraphic (sEMG) signal represents a challenge, due to the nature both stochastic and deterministic of the biopotential. The sEMG signal results from the superimposed activity of a high number of motor units, artifacts, and background noise. Among the different non-invasive techniques to measure the muscle electrical activity, recent studies showed how High-Density surface EMG (HD-sEMG) constitutes a very effective tool. HD-sEMG uses multiple closely spaced electrodes overlying a restricted area of the skin and provides high definition temporal and spatial information on muscle activity. To optimize the features of the current devices for HD-sEMG signal detection, this paper reports on the realization of the first inkjet printed HD electrode matrix. The matrix was built by inkjet printing of a commercial silver-based ink on a flexible Kapton® substrate. While bringing about all advantages of drop-on-demand inkjet technology, such as rapid prototyping and simple CAD re-desing of customizable devices, the printed matrix produces interesting electrical results in terms of resolution, resistance and electrode–skin contact impedance. Electrode–skin impedance obtained with our measurement setup was indeed always in line, while not better than the one obtained with commercial electrodes.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Muscle activation and electromyography studies · Advanced Sensor and Energy Harvesting Materials · Neuroscience and Neural Engineering
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Parker · J. Electromyogr. Kinesiol. · 2006 · 16 · 54110.1016/j.jelekin.2006.08.006 ↗
2. Merletti · 2004
3. Merletti · J. Electromyogr. Kinesiol. · 2008 · 18 · 87910.1016/j.jelekin.2008.09.002 ↗
4. Tanhehco · Phys. Med. Rehabil. Clin. North Am. · 2003 · 14 · 20710.1016/S1047-9651(02)00123-7 ↗
5. Basmajian · 1985
6. Zwarts · J. Electromyogr. Kinesiol. · 1989 · 83 · 441
7. Farina · Biomed. Signal Process. Control · 2008 · 3 · 13810.1016/j.bspc.2007.05.009 ↗
8. Farina · IEEE Trans. BME · 2000 · 47 · 38010.1109/10.827303 ↗
9. Day · J. Neurophysiol. · 2001 · 86 · 214410.1152/jn.2001.86.5.2144 ↗
10. De Luca · J. Biomech. · 2010 · 43 · 157310.1016/j.jbiomech.2010.01.027 ↗
11. Clancy · J. Electromyogr. Kinesiol. · 2002 · 12 · 110.1016/S1050-6411(01)00033-5 ↗
12. Zecca · Crit. Rev. Biomed. Eng. · 2002 · 30 · 45910.1615/CritRevBiomedEng.v30.i456.80 ↗
13. Kasman · 1998
14. Sella · Appl. Psycophysiol. Biofeedback · 2003 · 28 · 9310.1023/A:1023854423970 ↗
15. Hagg · J. Electromyogr. Kinesiol. · 2000 · 10 · 30110.1016/S1050-6411(00)00022-5 ↗
16. Hoozemans · J. Electromyogr. Kinesiol. · 2005 · 15 · 35810.1016/j.jelekin.2004.09.001 ↗
17. Clarys · J. Sports Sci. · 1993 · 11 · 37910.1080/02640419308730010 ↗
18. Katuntsev · Acta Astronaut. · 2009 · 64 · 68210.1016/j.actaastro.2008.11.015 ↗
19. Trappe · J. Appl. Physiol. · 2009 · 106 · 115910.1152/japplphysiol.91578.2008 ↗
20. Narici · J. Appl. Physiol. · 2011 · 111 · 40310.1007/s00421-010-1556-x ↗
21. Blok · Rev. Sci. Instrum. · 2002 · 73 · 188710.1063/1.1455134 ↗
22. Disselhorst-Klug · IEEE Trans. BME · 1997 · 44 · 56710.1109/10.594897 ↗
23. Farina · IEEE Trans. BME · 2003 · 50 · 35410.1109/TBME.2003.808830 ↗
24. Neuman · 1998
25. Geddes · 1975
26. Nambiar · Biosens. Bioelectron. · 2011 · 26 · 182510.1016/j.bios.2010.09.046 ↗
27. Singh · Adv. Mater. · 2010 · 22 · 67310.1002/adma.200901141 ↗
28. Chiolerio · Adv. Funct. Mater. · 2014 · 24 · 337510.1002/adfm.201303371 ↗
29. Ando · IEEE Instrum. Meas. Mag. · 2011 · 14 · 3610.1109/MIM.2011.6041380 ↗
30. Fully printed electronics on flexible substrates: high gain amplifiers and DAC10.1016/j.orgel.2013.12.027 ↗
31. Camarchia · Org. Electron. · 2014 · 15 · 9110.1016/j.orgel.2013.10.018 ↗
32. http://www.politronica.eu, 2014 (08.03.14).
33. http://www2.dupont.com/Kapton/en_US/, 2014 (08.03.14).
34. Lee · 2003
35. Silvert · J. Mater. Chem. · 1997 · 7 · 29310.1039/a605347e ↗
36. Hermens · J. Electromyogr. Kinesiol. · 2000 · 10 · 36110.1016/S1050-6411(00)00027-4 ↗
37. A. Bottin, P. Rebecchi, Impedance of the skin–electrode interface in surface EMG recordings, in: Proceedings of the XIV ISEK International Congress, June 22–25, Vienna, Austria, 2002.
38. Merletti · Clin. Biomech. · 2009 · 24 · 12210.1016/j.clinbiomech.2008.08.006 ↗
39. M. Paleari, M. Crepaldi, S. Stassi, E.P. Ambrosio, P. Ariano, G. Canavese, A. Chiolerio, V. Margaria, S. Ferraris, C.F. Pirri, Acta Astronautica (submitted for publication).