journal article·2018-03-01Open access

Spectroscopic OCT: towards an effective tool for distinguishing authentic and artificial Chinese freshwater pearls

Yang Zhou, Yang Zhao, Sanghoon Kim, Adam Wax

Optical Materials Express· Volume 8· Issue 3

Abstract

Distinguishing authentic and artificial Chinese freshwater pearls involves various tools and techniques, based primarily on visual inspection and spectroscopy. These methods are highly variable and thus not statistically reliable. This study investigates the capacity of spectroscopic optical coherence tomography (S-OCT) to classify authentic and artificial pearls in the NIR spectral range. The major advantage of S-OCT is that it allows spectroscopic measurements from within pearls, unlike traditional methods such as diffuse reflectance spectroscopy that primarily probe the surface. S-OCT spectral data was analyzed using principal component analysis (PCA) and partial least-squares discriminant analysis (PLSDA) to classify pearls. The implemented models successfully predicted pearl type and met performance metrics. The results show that S-OCT models could be used for more objective discrimination of authentic versus artificial pearls.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Optical Coherence Tomography Applications · Photoacoustic and Ultrasonic Imaging · Spectroscopy Techniques in Biomedical and Chemical Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. Fiske · Gems & Gemology · 2007 · 43 · 13810.5741/GEMS.43.2.138 ↗
2. Kiefert · Proc. SPIE · 2000 · 4098 · 24110.1117/12.401634 ↗
3. Aponick · J. Chem. Educ. · 1998 · 75 · 46510.1021/ed075p465 ↗
4. Bersani · Anal. Bioanal. Chem. · 2010 · 397 · 263110.1007/s00216-010-3700-1 ↗
5. Schrader · Talanta · 2000 · 53 · 3510.1016/S0039-9140(00)00385-4 ↗
6. Agatonovic-Kustrin · Mar. Drugs · 2012 · 10 · 145910.3390/md10071459 ↗
7. Nagai · Zool. Sci. · 2013 · 30 · 78310.2108/zsj.30.783 ↗
8. Krzemnicki · Gems & Gemology · 2010 · 46 · 12810.5741/GEMS.46.2.128 ↗
9. Rosc · Case Studies in Nondestructive Testing and Evaluation · 2016 · 6 · 3210.1016/j.csndt.2016.08.002 ↗
10. Ju · Opt. Express · 2011 · 19 · 642010.1364/OE.19.006420 ↗
11. Swanson · Biomed. Opt. Express · 2017 · 8 · 163810.1364/BOE.8.001638 ↗
12. Ju · Opt. Express · 2010 · 18 · 1346810.1364/OE.18.013468 ↗
13. Zhou · Sci. Rep. · 2016 · 6 · 3381910.1038/srep33819 ↗
14. Zhang · J. Biomed. Opt. · 2015 · 20 · 10090110.1117/1.JBO.20.10.100901 ↗
15. Robles · Nat. Photonics · 2011 · 5 · 74410.1038/nphoton.2011.257 ↗
16. Morgner · Opt. Lett. · 2000 · 25 · 11110.1364/OL.25.000111 ↗
17. Matthews · Optica · 2014 · 1 · 10510.1364/OPTICA.1.000105 ↗
18. Graf · J. Biomed. Opt. · 2009 · 14 · 06403010.1117/1.3269680 ↗
19. Zhao · Biomed. Opt. Express · 2015 · 6 · 333910.1364/BOE.6.003339 ↗
20. Nam · Appl. Spectrosc. Rev. · 2017 · 1324876 · 110.1080/05704928.2017.1324876 ↗
21. Su · Crit. Rev. Food Sci. Nutr. · 2017 · 57 · 103910.1080/10408398.2015.1082966 ↗
22. Vermeer · Biomed. Opt. Express · 2014 · 5 · 32210.1364/BOE.5.000322 ↗
23. Automated thickness measurements of nacre from optical coherence tomography using polar transform and probability density projection
24. Robles · Opt. Express · 2009 · 17 · 679910.1364/OE.17.006799 ↗