Sensitivity improvement by fusion splicing of single mode fibers with core offset
Source abstract
Abstract
We demonstrate a Fabry-Perot fiber cavity for strain measurement with highly improved sensitivity. The cavity is fabricated by the fusion splicing of two etched single-mode fibers with a core offset in the X axis or both X and Y axes. It is found that the strain sensitivity can be increased from 2.39 to 7.75pm/με by adopting offset splicing. Such a Fabry-Perot cavity device is compact in size, simple in structure, easy in fabrication and of low cost, and has high potential in strain sensing.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced Fiber Optic Sensors · Photonic and Optical Devices · Advanced Fiber Laser Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Liu · Opt. Lett. · 2014 · 39 · 212110.1364/OL.39.002121 ↗
2. Duan · Appl. Opt. · 2012 · 51 · 103310.1364/AO.51.001033 ↗
3. Crescent shaped Fabry-Perot fber cavity for ultra-sensitive strain measurement
4. Ferreira · Opt. Express · 2012 · 20 · 2194610.1364/OE.20.021946 ↗
5. Favero · Opt. Express · 2012 · 20 · 711210.1364/OE.20.007112 ↗
6. Lee · Sensors (Basel) · 2012 · 12 · 246710.3390/s120302467 ↗
7. Harris · Opt. Express · 2013 · 21 · 999610.1364/OE.21.009996 ↗
8. Rao · Opt. Express · 2007 · 15 · 1412310.1364/OE.15.014123 ↗
9. Liao · Opt. Express · 2012 · 20 · 2281310.1364/OE.20.022813 ↗
10. Liu · Sci. Rep. · 2015 · 5 · 762410.1038/srep07624 ↗
11. Yin · IEEE Photonics J. · 2014 · 6 · 110.1109/JPHOT.2014.2319101 ↗
12. Fabry-Perot sensor based on two coupled microspheres for strain measurement
13. Ferreira · Opt. Lett. · 2012 · 37 · 89010.1364/OL.37.000890 ↗
14. Ma · Opt. Lett. · 2012 · 37 · 249310.1364/OL.37.002493 ↗